A matched‐pair comparison of two different locking plates for valgus‐producing medial open‐wedge high tibial osteotomy: peek–carbon composite plate versus titanium plate
Bibliographic record
Abstract
PURPOSE: The first purpose of this study was to compare the clinical and radiographic outcome of two different locking plates used for valgus-producing medial open-wedge high tibial osteotomy (HTO). The second purpose was to histologically evaluate peek-carbon wear for biocompatibility. METHODS: Twenty-six consecutive patients undergoing open-wedge HTO using the first-generation PEEKPower HTO-Plate® (Group I) were matched with 26 patients after open-wedge HTO with the TomoFix™ plate (Group II). Clinical scores (visual analogue scale for pain, WOMAC, Lysholm score) were obtained preoperatively and at a minimum follow-up of 24 months postoperatively. Fixation stability was evaluated radiographically by comparing the medial proximal tibial angle (MPTA) and tibial slope 2 days after open-wedge HTO and after implant removal. Tissue samples of Group I were collected at the time of implant removal for histologic evaluation. RESULTS: Implant-related complications occurred in 15 % (n = 4) of Group I and 0 % of Group II. Out of them, 3 implant replacements were excluded from statistical analyses. After a final median follow-up of 25 months (range 24-31), the clinical scores in both groups showed significant improvements compared to preoperatively (visual analogue scale, WOMAC, Lysholm score; p < 0.001), without significant group differences (visual analogue scale, n.s.; WOMAC, n.s.; Lysholm score, n.s.). No significant differences between baseline and follow-up measurements for MPTA and tibial slope were observed within each group (MPTA: Gr. I, n.s.; Gr. II, n.s.; tibial slope: Gr. I, n.s.; Gr. II, n.s.) or between the two groups (MPTA, n.s.; tibial slope, n.s.). In histologic samples, CF PEEK abrasion did not induce inflammation or tissue necrosis. CONCLUSION: The first-generation PEEKPower HTO-Plate® provided a higher rate of implant-related complications compared to the TomoFix™ plate at a minimum follow-up of 24 months after valgus-producing open-wedge HTO. Therefore, it is not recommended to use the first-generation PEEKPower HTO-Plate® in the clinical practice. LEVEL OF EVIDENCE: III.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.001 | 0.003 |
| Meta-epidemiology (narrow) | 0.001 | 0.000 |
| Meta-epidemiology (broad) | 0.001 | 0.001 |
| Bibliometrics | 0.001 | 0.000 |
| Science and technology studies | 0.000 | 0.001 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.001 | 0.000 |
| Research integrity | 0.001 | 0.000 |
| Insufficient payload (model declined to judge) | 0.003 | 0.001 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".