MétaCan
Menu
← all works

Stability of Self-Assembled Polymeric Micelles in Serum

2011· article· en· 300 citations· W2043461452 on OpenAlex· 10.1021/ma200675w

Why is this work in the frame?

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

Canadian affiliationAn author listed a Canadian institution. This is the only route the usual frame has.

Full frame distilled prediction

Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

Candidate categories
Insufficient payload (model declined to judge)
Consensus categories
none
Domain
Candidate signal: noneConsensus signal: none
Study design
Candidate signal: Bench or experimentalConsensus signal: Bench or experimental
Genre
Candidate signal: EmpiricalConsensus signal: Empirical
Teacher disagreement score
0.176
Threshold uncertainty score
1.000
Validation status
machine_predicted_unvalidated · codex-gemma-dda1882f352a

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Opus teacher head0.017
GPT teacher head0.212
Teacher spread
0.195 · how far apart the two teachers sit on this one work
Validation status
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Abstract

The stability of polymeric nanoparticles in serum is critical to their use in drug delivery where dilution after intravenous injection often results in nanoparticle disassembly and drug unloading; however, few investigate this in biologically relevant media. To gain greater insight into nanoparticle stability in blood, the stability of self-assembled polymeric micelles of poly(d,l-lactide-co-2-methyl-2-carboxytrimethylene carbonate)-g-poly(ethylene glycol), P(LA-co-TMCC)-g-PEG, were tested in both serum and individual serum protein solutions. By encapsulating Förster resonance energy transfer pairs and following their release by fluorescence, these micelles demonstrated excellent thermodynamic and kinetic stability in the presence of serum. Further analyses by fast protein liquid chromatography and dynamic light scattering confirmed these data. Moreover, these micelles are compatible with red blood cells, as shown by a hemolysis assay. The stability and compatibility demonstrated in blood suggest that these micelles may be stable in vivo, which is critical for intravenous drug delivery applications. This comprehensive approach to understanding micelle stability and compatibility is broadly applicable.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

The record

Venue
Macromolecules
Topic
Surfactants and Colloidal Systems
Field
Chemistry
Canadian institutions
University of Toronto
Funders
not available
Keywords
MicelleDynamic light scatteringChemistryEthylene glycolHemolysisNanoparticleDrug carrierDilutionDrug deliveryChromatographyPEG ratioChemical engineeringMaterials scienceOrganic chemistryNanotechnologyAqueous solution
Has abstract in OpenAlex
yes