MétaCan
Menu
Back to cohort
Record W2045429977 · doi:10.1097/opx.0b013e31824c0c4a

Impact of Tear Film Components on Lysozyme Deposition to Contact Lenses

2012· article· en· W2045429977 on OpenAlexaff
Alan Ng, Miriam Heynen, Doerte Luensmann, Lyndon Jones

Bibliographic record

VenueOptometry and Vision Science · 2012
Typearticle
Languageen
FieldMedicine
TopicOcular Surface and Contact Lens
Canadian institutionsUniversity of Waterloo
Fundersnot available
KeywordsLysozymeSilicone hydrogelLactoferrinChemistryArtificial tearsLens (geology)Deposition (geology)ChromatographyBiochemistryOphthalmologyContact lensOpticsMedicineBiology

Abstract

fetched live from OpenAlex

PURPOSE: To investigate the impact of lactoferrin and lipids on the kinetic deposition of lysozyme on silicone and conventional hydrogel lenses, using a complex artificial tear solution (ATS). METHODS: Two silicone hydrogel lenses (AIR OPTIX AQUA; lotrafilcon B and ACUVUE OASYS; senofilcon A) and two conventional hydrogel lenses (ACUVUE 2; etafilcon A and PROCLEAR; omafilcon A) were investigated. Lenses were incubated in four different solutions: a complex ATS consisting of various salts, lipids, proteins, and mucins, an ATS without lactoferrin (ATS w/o Lac), an ATS without lipids (ATS w/o Lip), and an ATS without lactoferrin and lipids (ATS w/o Lac & Lip), each containing 2% radiolabeled (125I) lysozyme (1.9 mg/ml). After each time point (4, 12 h and 1, 2, 3, 5, 7, 14, 21, 28 days), the amount of lysozyme per lens was quantified. RESULTS: After 28 days, lotrafilcon B lenses incubated in ATS deposited significantly less lysozyme (9.7 ± 1.4 μg) than when incubated in solutions not containing lactoferrin and lipids (more than 11.8 μg) (p < 0.001). Lysozyme uptake to senofilcon A lenses was higher in ATS w/o Lip (5.3 ± 0.1 μg) compared with other solutions (less than 3.9 μg) (p < 0.001). Etafilcon A lenses deposited the most lysozyme in all four solutions compared with the rest of the lens types (p < 0.001). For etafilcon A lenses, less lysozyme was deposited when incubated in ATS w/o Lip (588.6 ± 0.4 μg) compared with the other solutions (more than 642.6 μg) (p < 0.001). Omafilcon A lenses in ATS w/o Lac accumulated significantly less lysozyme (12.8 ± 1.0 μg) compared with the other solutions (more than 14.2 μg) (p < 0.001). CONCLUSIONS: An ATS containing lactoferrin and lipids impacts lysozyme deposition on both silicone and conventional hydrogel contact lenses. When performing in vitro experiments to study protein deposition on contact lenses, more complex models should be used to better mimic the human tear film.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.003

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.022
GPT teacher head0.425
Teacher spread0.403 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations32
Published2012
Admission routes1
Has abstractyes

Explore more

Same venueOptometry and Vision ScienceSame topicOcular Surface and Contact LensFrench-language works237,207