MétaCan
Menu
Back to cohort
Record W2046656454 · doi:10.1080/02786820600615055

Experimental Measurement and Numerical Study of Particle Deposition in Highly Idealized Mouth-Throat Models

2006· article· en· W2046656454 on OpenAlexaff
Yu Zhang, Tze Luck Chia, Warren H. Finlay

Bibliographic record

VenueAerosol Science and Technology · 2006
Typearticle
Languageen
FieldMedicine
TopicInhalation and Respiratory Drug Delivery
Canadian institutionsUniversity of Alberta
Fundersnot available
KeywordsDeposition (geology)Particle (ecology)Particle depositionThroatMechanicsAerosolPhysicsEnvironmental scienceMeteorologyGeologyGeomorphologyMedicine

Abstract

fetched live from OpenAlex

Particle deposition in the human mouth-throat is an important factor in evaluating efficiency of drug delivered by inhalation devices, such as pMDIs or DPIs. Current USP standard impactor induction ports (which serve as an in vitro representative of the adult mouth-throat) underpredict in vivo mouth-throat deposition. However, preliminary experimental data in the prototype geometry of a highly idealized mouth-throat has indicated that it is a promising replacement for the USP mouth-throat (CitationZhang et al. 2004). In this study, partial optimization design of the highly idealized mouth-throat was performed using computational fluid dynamics (CFD) simulations. The performance of six candidate highly idealized mouth-throat geometries, each with a straight tube inlet of inner diameter 17.3 mm, was evaluated experimentally by measuring monodisperse particle deposition efficiency. Gravimetry was used to determine particle deposition in these geometries. Monodisperse particles of di-2-ethylhexyl-sebecate (DEHS) oil with mass median diameters of 2.1–7.5 μm (GSD < 1.1) were used at two steady inhalation flow rates of 30 and 90 l/min. The results showed that, at the higher flow rate of 90 l/min, a mouth-throat with a bend region 8.5 mm in diameter and a curvature radius of 50 mm follows the in vivo average summarized by CitationStahlhofen et al. (1989) most closely. In contrast, at the lower flow rate of 30 l/min, the mouth-throat with a bend region 7.5 mm in diameter mimics the above in vivo curve but the in vivo-in vitro match is worse than for 90 l/min case. Enhanced particle deposition caused by a Reynolds number effect was observed in all geometries studied. Overall, an adequately designed highly idealized mouth-throat can largely reproduce in vivo mouth-throat deposition. For different flow rates, different key dimensions are required with the present highly idealized mouth-throats in order to adequately reproduce the in vivo average curve.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.006

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.026
GPT teacher head0.274
Teacher spread0.248 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations62
Published2006
Admission routes1
Has abstractyes

Explore more

Same venueAerosol Science and TechnologySame topicInhalation and Respiratory Drug DeliveryFrench-language works237,207