MétaCan
Menu
Back to cohort
Record W2047582838 · doi:10.1371/journal.pone.0106498

Isolated Assessment of Translation or Rotation Severely Underestimates the Effects of Subject Motion in fMRI Data

2014· article· en· W2047582838 on OpenAlexfundno aff
Marko Wilke

Bibliographic record

VenuePLoS ONE · 2014
Typearticle
Languageen
FieldMedicine
TopicAdvanced MRI Techniques and Applications
Canadian institutionsnot available
FundersNational Institute of Neurological Disorders and StrokeNational Institute of Mental HealthHector StiftungDeutsche ForschungsgemeinschaftNational Institutes of HealthEunice Kennedy Shriver National Institute of Child Health and Human DevelopmentImperial College LondonMcGill University
KeywordsMotion (physics)Measure (data warehouse)Set (abstract data type)Computer scienceOutlierTrajectoryRotation (mathematics)Data setTranslation (biology)Artificial intelligenceFunctional magnetic resonance imagingQuality (philosophy)MathematicsStatisticsPsychologyData miningPhysicsNeuroscienceChemistry

Abstract

fetched live from OpenAlex

Subject motion has long since been known to be a major confound in functional MRI studies of the human brain. For resting-state functional MRI in particular, data corruption due to motion artefacts has been shown to be most relevant. However, despite 6 parameters (3 for translations and 3 for rotations) being required to fully describe the head's motion trajectory between timepoints, not all are routinely used to assess subject motion. Using structural (n = 964) as well as functional MRI (n = 200) data from public repositories, a series of experiments was performed to assess the impact of using a reduced parameter set (translationonly and rotationonly) versus using the complete parameter set. It could be shown that the usage of 65 mm as an indicator of the average cortical distance is a valid approximation in adults, although care must be taken when comparing children and adults using the same measure. The effect of using slightly smaller or larger values is minimal. Further, both translationonly and rotationonly severely underestimate the full extent of subject motion; consequently, both translationonly and rotationonly discard substantially fewer datapoints when used for quality control purposes ("motion scrubbing"). Finally, both translationonly and rotationonly severely underperform in predicting the full extent of the signal changes and the overall variance explained by motion in functional MRI data. These results suggest that a comprehensive measure, taking into account all available parameters, should be used to characterize subject motion in fMRI.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.018
metaresearch head score (Gemma)0.055
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.018
Threshold uncertainty score0.096

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0180.055
Meta-epidemiology (narrow)0.0020.001
Meta-epidemiology (broad)0.0020.001
Bibliometrics0.0010.002
Science and technology studies0.0010.002
Scholarly communication0.0020.001
Open science0.0010.002
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.092
GPT teacher head0.356
Teacher spread0.264 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations33
Published2014
Admission routes1
Has abstractyes

Explore more

Same venuePLoS ONESame topicAdvanced MRI Techniques and ApplicationsFrench-language works237,207