Provisioning Substation-level authentication in the smart grid networks
Bibliographic record
Abstract
A large number of modern Intelligent Electronic Devices (IEDs) are installed in the Substations for equipment monitoring. In viewing the vision of Smart Grid, these devices provide valuable information that can be put to use to improve reliability and reduce operating costs. In order to integrate IEDs, the utilities are also deploying extensive modern communication networks. However, there is a growing concern about the security of Supervisory Control and Data Acquisition systems (SCADA). Providing secure remote access to substation devices for maintenance is much more challenging than just allowing SCADA to access substation equipment. We propose a lightweight and efficient solution for Substation-level authentication using server-aided verification mechanism in which IEDs and other resource-constrained devices can be authenticated by any remote users with help of the substation controller (SSC). We illustrate that the proposed mechanism can provide better security than the existing ones.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".