MétaCan
Menu
Back to cohort
Record W2048352997 · doi:10.1118/1.3438476

Fast‐marching segmentation of three‐dimensional intravascular ultrasound images: A pre‐ and post‐intervention study

2010· article· en· W2048352997 on OpenAlexafffund
Marie‐Hélène Roy Cardinal, Gilles Soulez, Jean‐Claude Tardif, Jean Meunier, Guy Cloutier

Bibliographic record

VenueMedical Physics · 2010
Typearticle
Languageen
FieldMedicine
TopicCoronary Interventions and Diagnostics
Canadian institutionsMontreal Heart InstituteMontreal Clinical Research InstituteUniversité de Montréal
FundersFonds de Recherche du Québec - SantéNatural Sciences and Engineering Research Council of Canada
KeywordsIntravascular ultrasoundFast marching methodSegmentationLumen (anatomy)UltrasoundArtificial intelligenceImage segmentationComputer scienceComputer visionSpeckle noiseBiomedical engineeringRadiologyMedicineSpeckle patternSurgery

Abstract

fetched live from OpenAlex

PURPOSE: Intravascular ultrasound (IVUS) is a vascular imaging technique that is used to study atherosclerosis since it has the ability to show the lumen and the vessel wall. Cross-sectional images of blood vessels are produced and they provide quantitative assessment of the vascular wall, information about the nature of atherosclerotic lesions, as well as the plaque shape and size. Due to the ultrasound speckle, catheter artifacts, or calcification shadows, the automated analysis of large IVUS data sets represents an important challenge. METHODS: A multiple interface 3D fast-marching method is presented for the detection of the lumen and external vessel wall boundaries. The segmentation is based on a combination of region and contour information, namely, the gray level probability density functions of the vessel structures and the intensity gradient. The detection of the lumen boundary is fully automatic. The segmentation method includes an interactive initialization procedure of the external vessel wall border. The segmentation method was applied to 20 in vivo IVUS data sets acquired from femoral arteries. This database contained three subgroups: Pullbacks acquired before balloon angioplasty (n=7), after the intervention (n=7), and at a 1 yr follow-up examination (n=6). Results were compared to validation contours that were manually traced by two experts on more than 1500 individual frames. RESULTS: For all subgroups, no significant difference was found between the area measurements of the segmentation and validation contours for the lumen and external vessel wall. Moreover, high intraclass correlation coefficients (> 0.96) between the area of the manually traced contours and detected boundaries with the fast-marching method were obtained for both vessel layers over the whole database. The segmentation performance was also evaluated with point-to-point contour distances between segmentation results and manually traced contours. A good overall accuracy was obtained with average distances < 0.13 mm and maximum distances < 0.46 mm, indicating a good performance in regions lacking information or containing artifacts. Only small differences of less than a pixel (0.02 mm) were observed between the average distance metrics of each subgroup, which prove the segmentation consistency. CONCLUSIONS: This new IVUS segmentation method provides accurate results that correspond well to the experts' manually traced contours, but requires much less manual interactions and is faster.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.642
Threshold uncertainty score0.456

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.009
GPT teacher head0.296
Teacher spread0.287 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations46
Published2010
Admission routes2
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicCoronary Interventions and DiagnosticsFrench-language works237,207