Isoflurane Dosage for Equivalent Intraoperative Electroencephalographic Suppression in Patients With and Without Epidural Blockade

2002· article· en· W2048943258 on OpenAlexaff
Andrew P. Morley, James L. Derrick, Paul T. Seed, Perpetua E. Tan, David C. Chung, Timothy G. Short

Bibliographic record

VenueAnesthesia & Analgesia · 2002
Typearticle
Languageen
FieldMedicine
TopicAnesthesia and Sedative Agents
Canadian institutionsWomen's Health Research Institute
Fundersnot available
KeywordsMedicineIsofluraneAnesthesiaBispectral indexAlfentanilBradycardiaHeart rateConfidence intervalBurst suppressionPropofolBlood pressureElectroencephalographyInternal medicine

Abstract

fetched live from OpenAlex

UNLABELLED: We conducted a prospective, randomized, controlled trial to establish the effect of epidural blockade on isoflurane requirements for equivalent intraoperative electroencephalographic (EEG) suppression. Fifty patients undergoing abdominal hysterectomy received combined epidural and general anesthesia or general anesthesia alone with isoflurane and alfentanil. Isoflurane was administered by computer-controlled closed-loop feedback to maintain an EEG 95% spectral edge frequency of 17.5 Hz, a target chosen on the basis of a pilot study. In epidural patients, end-tidal isoflurane concentration (FE'(ISO)) was 0.19% smaller (95% confidence interval [CI], -0.32% to -0.06%; P < 0.01), mean arterial blood pressure was 17 mm Hg lower (95% CI, -24 to -9 mm Hg; P < 0.0001), and body temperature was 0.4 degrees C lower (95% CI, -0.7 to 0 degrees C; P < 0.05) than in controls. EEG bispectral index (BIS) was 4 points higher (95% CI, 1 to 7; P < 0.05). EEG median frequency and heart rate were similar in both groups. Epidural patients were 76% more likely (95% CI, 58% to 94%; P < 0.001) to require metaraminol for hypotension and were 28% more likely (95% CI, 3% to 53%; P < 0.05) to require glycopyrrolate for bradycardia. After surgery, the time to eye opening in epidural patients was 2.3 min shorter (95% CI, -4.2 to -0.5 min; P < 0.05). Time to eye opening correlated better with FE'(ISO) in the last 30 s of anesthesia (FE'(ISO) = 0.07 x time to eye opening + 0.31; r(2) = 0.59; P < 0.0001) than with BIS from the same period (BIS = 64 - 1.25 x time to eye opening; r(2) = 0.22; P < 0.001) (P < 0.0001). To maintain similar intraoperative spectral edge frequency, patients receiving combined epidural and general anesthesia require 21% less isoflurane than those receiving general anesthesia alone. This smaller isoflurane dose is associated with faster emergence from anesthesia. IMPLICATIONS: The dose of general anesthetic required to maintain similar intraoperative suppression of brain electrical activity is 21% less in patients with nerve blockade than in those without. This dose reduction results in faster waking times in patients with nerve blockade, which may reflect lighter intraoperative anesthesia. The dose of general anesthetic required to maintain similar intraoperative suppression of brain electrical activity is 21% less in patients with nerve blockade than in those without. This dose reduction results in faster waking times in patients with nerve blockade, which may reflect lighter intraoperative anesthesia.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.007
Threshold uncertainty score0.993

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.014
GPT teacher head0.242
Teacher spread0.228 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations15
Published2002
Admission routes1
Has abstractyes

Explore more

Same venueAnesthesia & AnalgesiaSame topicAnesthesia and Sedative AgentsFrench-language works237,207