MétaCan
Menu
Back to cohort
Record W2049371600 · doi:10.1039/b212727j

Flame photometric detection inside of a capillary gas chromatography column

2003· article· en· W2049371600 on OpenAlexafffund
Kevin B. Thurbide, Christine D. Anderson

Bibliographic record

VenueThe Analyst · 2003
Typearticle
Languageen
FieldChemistry
TopicAnalytical Chemistry and Chromatography
Canadian institutionsUniversity of Calgary
FundersNatural Sciences and Engineering Research Council of Canada
KeywordsGas chromatographyAnalytical Chemistry (journal)ChemistrySulfurDetection limitChromatographyCapillary actionHydrogenOxygenMaterials scienceComposite materialOrganic chemistry

Abstract

fetched live from OpenAlex

A novel micro-flame photometric detector (FPD) employing a miniature counter-current flame is described. The micro-FPD flame, encompassing a volume of about 30 nL, is operated inside the end of a capillary gas chromatography column (i.e. on-column) or inside of a quartz capillary after the column (i.e. post-column). Either air or oxygen can support a hydrogen flame in the device, although oxygen is far preferable. The detector can be operated for several hours without any observed degradation in performance or flame stability. The optimal gas flows established for the detection of sulfur and phosphorus are in the range of 4 mL min(-1) of oxygen and 9 to 13 mL min(-1) of hydrogen. The fuel-rich micro-FPD flame generates chemiluminescent blue S2* emission for sulfur and green HPO* emission for phosphorus, similar to a conventional FPD. Sulfur response in the micro-FPD is quadratic over nearly 3 orders of magnitude while that of phosphorus is linear over nearly 5 orders of magnitude. The micro-FPD detection limit for sulfur is 1 x 10(-9) g S s(-1), and that of phosphorus is 2 x 10(-10) g P s(-1). The properties established for the initial prototype of the micro-FPD make this counter-current flame method potentially suitable for integration with on-chip gas chromatography or other micro-analytical devices where flame-based detection methods are desirable.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Methods · Consensus signal: Methods
Teacher disagreement score0.002
Threshold uncertainty score0.008

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0010.000
Scholarly communication0.0010.001
Open science0.0020.001
Research integrity0.0020.001
Insufficient payload (model declined to judge)0.0020.002

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.008
GPT teacher head0.211
Teacher spread0.203 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations16
Published2003
Admission routes2
Has abstractyes

Explore more

Same venueThe AnalystSame topicAnalytical Chemistry and ChromatographyFrench-language works237,207