MétaCan
Menu
← Back to cohort
Record W2049562562 · doi:10.1117/12.592181

Enzymatic detection of troponin C and melittin bee

2005· article· en· W2049562562 on OpenAlexafffund
Amritsar Jeetender, Ion Stiharu, Muthukumaran Packirisamy

Bibliographic record

VenueProceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · 2005
Typearticle
Languageen
FieldMedicine
TopicHealthcare and Venom Research
Canadian institutionsConcordia University
FundersConcordia University
KeywordsBiosensorMelittinTroponin CImmunoassayAnalyteTroponinTroponin IMyocardial infarctionNanotechnologyComputer scienceAntibodyMaterials scienceChemistryMedicineBiochemistryImmunologyInternal medicineChromatographyPeptide

Abstract

fetched live from OpenAlex

One of the major goals of biosensor technology is to detect and quantify in detail analytes with very high accuracy. To achieve this, much of the emphasis in sensor fabrication has been laid on antibody-antigen interaction. The consequence of this focus of enzyme biosensor studies is the development of critical techniques which can be extended in the detection of Acute Myocardial Infarction (AMI). Biosensors for AMI have attracted considerable interest in the last few years since the monitoring of a specific substance is central in enzymatic reactions. This interest has led to the investigation of biochemical markers of myocardial injury. These biomarkers facilitate the diagnosis and treatment of patients with AMI. Serial measurements of biochemical markers are now universally accepted as an important determinant in AMI diagnosis. Due to their high sensitivity and specificity over other biomarkers, the troponins are the markers of choice for the diagnosis or exclusion of AMI. The present techniques used in the identification of the troponins are lengthy and require large amount of specimen solution. The present research is directed towards the identification of optical detection procedures that are compatible to the miniaturization. In the present study an effort has been made to study the antigen-antibody reaction of rabbit skeletal muscle troponin C (TnC) and bee venom melittin (ME). Fluorescence energy transfer experiments were done to investigate the Ca 2+ -dependant interaction of TnC-ME in a 1:1 complex. Experiments were also conducted on TnC-ME binding at different ratios. These results validate the biosensor technology and illustrate how a biosensor can be developed based on the study of interaction between monoclonal antibody and antigen reaction in real time. The reported experimental results provide valuable information that will be useful in the development of a biosensor for the detection of AMI.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.002

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.019
GPT teacher head0.284
Teacher spread0.266 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2005
Admission routes2
Has abstractyes

Explore more

Same venueProceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE→Same topicHealthcare and Venom Research→French-language works237,207→