MétaCan
Menu
Back to cohort
Record W2050180477 · doi:10.3415/vcot-11-04-0065

Effect of the length of the superficial plate on bending stiffness, bending strength and strain distribution in stacked 2.0–2.7 veterinary cuttable plate constructs

2011· article· en· W2050180477 on OpenAlexafffund
Thomas W. G. Gibson, N M M Moens, R J Runciman, D. Grant Allen, G M Monteith, Sylvain Bichot

Bibliographic record

VenueVeterinary and Comparative Orthopaedics and Traumatology · 2011
Typearticle
Languageen
FieldMedicine
TopicSurgical Sutures and Adhesives
Canadian institutionsUniversity of Guelph
FundersOVC Pet Trust
KeywordsStiffnessBending stiffnessBendingStress (linguistics)Materials scienceDeformation (meteorology)Composite materialImplantYield (engineering)MedicineRodOrthodonticsStructural engineeringBiomedical engineeringSurgeryPathology

Abstract

fetched live from OpenAlex

OBJECTIVES: Use of stacked veterinary cuttable plates (VCP) increases the construct stiffness, but it also increases the stress protection and concentrates the stress at the extremities of the implants. We hypothesized that by shortening the superficial plate, it would not reduce the stiffness of the construct, but that it would reduce the stress concentration at the plate ends. METHODS: A 3 mm fracture gap model was created with copolymer acetal rods, stacked 2.0-2.7 VCP and 2.7 screws. The constructs consisted of an 11-hole VCP bottom plate and a 5-, 7-, 9- or 11-hole VCP superficial plate. Five of each construct were randomly tested for failure in four-point bending and axial loading. Stiffness, load at yield, and area under the curve until contact (AUC) were measured. Strains were recorded during elastic deformation for each configuration. RESULTS: During both testing methods, stiffness, load at yield and AUC progressively decreased when decreasing the length of the superficial plate. No statistically significant differences were obtained for load at yield in four-point bending and AUC in axial loading. The strain within the implant over the gap increased as the length of the superficial plate decreased. CLINICAL SIGNIFICANCE: Shortening the superficial plate reduces the stiffness and strength of the construct, and decreases stress concentration at the implants ends. As the cross section of the implant covering the gap remained constant, friction between the plates may play a role in the mechanical properties of stacked VCP.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.125
Threshold uncertainty score0.459

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.061
GPT teacher head0.296
Teacher spread0.235 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations11
Published2011
Admission routes2
Has abstractyes

Explore more

Same venueVeterinary and Comparative Orthopaedics and TraumatologySame topicSurgical Sutures and AdhesivesFrench-language works237,207