MétaCan
Menu
Back to cohort
Record W2050485681 · doi:10.1088/0031-9155/53/18/016

Image registration of a moving target phantom with helical tomotherapy: effect of the CT acquisition technique and action level proposal

2008· article· en· W2050485681 on OpenAlexafffund
Curtis Woodford, Slav Yartsev, Jake Van Dyk

Bibliographic record

VenuePhysics in Medicine and Biology · 2008
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsLondon Health Sciences Centre
FundersOntario Institute for Cancer Research
KeywordsTomotherapyImaging phantomImage registrationNuclear medicineResidualComputer visionComputer scienceArtificial intelligenceMedicineRadiologyRadiation therapyAlgorithmImage (mathematics)

Abstract

fetched live from OpenAlex

This study aims to quantify the effects of target motion and resultant motion artifacts in planning and megavoltage CT (MVCT) studies on the automatic registration processes of helical tomotherapy. Clinical and experimental data were used to derive an action level for patient repositioning on helical tomotherapy. Planning CT studies of a respiratory motion phantom were acquired using conventional and four-dimensional CT (4D CT) techniques. MVCT studies were acquired on helical tomotherapy in the presence and absence of target motion and were registered with different planning CT studies. The residual errors of the registration process were calculated from the registration values to quantify the ability of the process to detect 5 or 10 mm translations of the phantom in two directions. Twenty-seven registration combinations of MVCT inter-slice spacing, technique and resolution were investigated. The residual errors were used as an estimate of the localization error of the registration process, and the accuracy of couch repositioning was determined from couch position measurements during 866 treatment fractions. These two parameters were used to calculate the action level for patient repositioning on helical tomotherapy. Automatic registration of an MVCT study with 0% breathing phase, average intensity and maximum intensity 4D CT projections did not differ from that of an MVCT study with a conventional planning CT. Motion artifacts in the MVCT or planning CT studies changed the accuracy of the automatic registration process by less than 2.0%. The action level for patient repositioning using MVCT studies of 6 mm inter-slice spacing was determined to be 0.7, 1.1 and 0.6 mm in the x-, y- and z-directions, respectively. These action levels have the greatest effect on treatments for disease sites in the brain.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.012
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.014

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0030.012
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.058
GPT teacher head0.366
Teacher spread0.308 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations9
Published2008
Admission routes2
Has abstractyes

Explore more

Same venuePhysics in Medicine and BiologySame topicAdvanced Radiotherapy TechniquesFrench-language works237,207