MétaCan
Menu
Back to cohort
Record W2051170794 · doi:10.1016/j.juro.2009.01.039

The Adjustable Continence Therapy System for Recurrent Female Stress Urinary Incontinence: 1-Year Results of the North America Clinical Study Group

2009· article· en· W2051170794 on OpenAlexaff
Sherif R. Aboseif, Ethan I. Franke, Steven Nash, Joel Slutsky, Neil Baum, Le Mai Tu, Niall T.M. Galloway, Peter Pommerville, Suzette E. Sutherland, John F. Bresette

Bibliographic record

VenueThe Journal of Urology · 2009
Typearticle
Languageen
FieldMedicine
TopicPelvic floor disorders treatments
Canadian institutionsHôpital Fleurimont
Fundersnot available
KeywordsMedicineLabia majoraUrinary incontinenceStress incontinenceSurgeryQuality of life (healthcare)Adverse effectUrinary systemUrologyInternal medicineVulva

Abstract

fetched live from OpenAlex

PURPOSE: We determined the efficacy, safety, adjustability and technical feasibility of the adjustable continence therapy device (Uromedica, Plymouth, Minnesota) for the treatment of recurrent female stress urinary incontinence. MATERIALS AND METHODS: Female patients with recurrent stress urinary incontinence were enrolled in the study and a defined set of exclusionary criteria were followed. Baseline and regular followup tests to determine eligibility, and to measure subjective and objective improvement were performed. A trocar was passed fluoroscopically and with digital vaginal guidance to the urethrovesical junction through small incisions between the labia majora and minora. The adjustable continence therapy device was delivered and the balloons were filled with isotonic contrast. The injection ports for balloon inflation were placed in a subcutaneous pocket in each labia majora. Device adjustments were performed percutaneously in the clinic postoperatively. An approved investigational device exemption Food and Drug Administration protocol was followed to record all adverse events. RESULTS: A total of 162 subjects underwent implantation with 1 year of data available on 140. Mean Stamey score improved by 1 grade or more in 76.4% (107 of 140) of subjects. Improvement in the mean incontinence quality of life questionnaire score was noted at 36.5 to 70.7 (p <0.001). Reductions in mean Urogenital Distress Inventory (60.3 to 33.4) and Incontinence Impact Questionnaire (54.4 to 23.4) scores also occurred (p <0.001). Mean provocative pad weight decreased from 49.6 to 11.2 gm (p <0.001). Of the patients 52% (67 of 130) were dry at 1 year (less than 2 gm on provocative pad weight testing) and 80% (102 of 126) were improved (greater than 50% reduction on provocative pad weight testing). Complications occurred in 24.4% (38 of 156) of patients. Explantation was required in 18.3% (28 of 153) of the patients during 1 year. In terms of the complications 96.0% were considered to be mild or moderate. CONCLUSIONS: The Uromedica adjustable continence therapy device is an effective, simple, safe and minimally invasive treatment for recurrent female stress urinary incontinence. It can be easily adjusted percutaneously to enhance efficacy and complications are usually easily manageable. Explantation does not preclude later repeat implantation.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.182
Threshold uncertainty score0.285

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.028
GPT teacher head0.324
Teacher spread0.295 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations40
Published2009
Admission routes1
Has abstractyes

Explore more

Same venueThe Journal of UrologySame topicPelvic floor disorders treatmentsFrench-language works237,207