MétaCan
Menu
Back to cohort
Record W2051866842 · doi:10.1055/s-2008-1077720

Hybrid natural orifice transluminal endoscopic surgery (NOTES) for Roux-en-Y gastric bypass: an experimental surgical study in human cadavers

2008· article· en· W2051866842 on OpenAlexaff
Mary E. Hagen, O Wagner, Paul Swain, François Pugin, Nicolas C. Buchs, M. Caddedu, Priya A. Jamidar, Jean Fasel, P. Morel

Bibliographic record

VenueEndoscopy · 2008
Typearticle
Languageen
FieldMedicine
TopicMinimally Invasive Surgical Techniques
Canadian institutionsMcMaster University
Fundersnot available
KeywordsMedicineRoux-en-Y anastomosisNatural orifice transluminal endoscopic surgeryGastric bypassCadaverSurgeryEsophagogastric junctionEndoscopyEndoscopic surgeryTransplant surgeryGeneral surgeryLaparoscopyInternal medicineCancer

Abstract

fetched live from OpenAlex

BACKGROUND AND STUDY AIMS: The advantages of a hybrid natural orifice transluminal endoscopic surgery approach to Roux-en-Y gastric bypass (hNOTES-RYGBP) might include: easier access to the peritoneal cavity, reduced number of ports and related complications, improved cosmesis, and others. However, currently available conventional endoscopic and laparoscopic instruments might be unsuitable for complex surgical procedures using transluminal access. The aim of this study was to investigate the feasibility and limitations of a NOTES RYGBP. METHODS: hNOTES-RYGBP was performed in human cadavers. Pouch creation was achieved by needle-knife dissection using a transvaginal, flexible scope. Articulating linear staplers were placed transumbilically to transect the stomach. Measurements of the small bowel were accomplished intraluminally or with flexible and rigid graspers. New methods were tested to create the gastro-jejunal anastomosis. A linear laparoscopic stapler was used to form the jejuno-jejunal anastomosis. RESULTS: Stapler manipulation and anvil docking, bowel manipulation and measurement, and tissue dissection presented the main obstacles for hNOTES-RYGBP. Conventional instruments were too short for some transvaginal manipulations. The time to complete the procedure was 6 - 9 hours. It was feasible to perform a complete hNOTES-RYGBP in four out of seven cadavers. Two cadavers were unsuitable due to anatomical abnormalities or advanced decay. One procedure was terminated before completion because of time constraints. Combinations of flexible and rigid visualization and manipulation were helpful, especially for dissection and gastric pouch creation. CONCLUSIONS: Several factors made hNOTES-RYGBP very challenging and time-consuming. A lack of proper instrumentation resulting in insufficient tissue traction, countertraction, and instrument manipulation complicated several steps during the procedure. A combination of flexible with rigid endoscopic techniques offers specific advantages for components of this type of surgery. Changes in instrument design are required to improve more complex endosurgical procedures.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.007
Threshold uncertainty score0.023

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0030.001
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.000
Science and technology studies0.0010.002
Scholarly communication0.0000.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0070.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.053
GPT teacher head0.351
Teacher spread0.298 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations34
Published2008
Admission routes1
Has abstractyes

Explore more

Same venueEndoscopySame topicMinimally Invasive Surgical TechniquesFrench-language works237,207