MétaCan
Menu
← Back to cohort
Record W2052052486 · doi:10.1118/1.4740202

Sci—Fri PM: Delivery — 07: Cyberknife relative output factor measurements using fiber‐coupled luminescence, MOSFETS and RADPOS dosimetry system

2012· article· en· W2052052486 on OpenAlexaffabout
Nicolas Ploquin, Gustavo Kertzscher, Eric Vandervoort, JE Cygler, C.E. Andersen, Paolo Francescon

Bibliographic record

VenueMedical Physics · 2012
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsCarleton UniversityOttawa HospitalUniversity of Ottawa
Fundersnot available
KeywordsDosimetryRadioluminescenceMaterials scienceImaging phantomOptically stimulated luminescenceDetectorMonte Carlo methodOpticsPhysicsNuclear medicineMedicineMathematics

Abstract

fetched live from OpenAlex

Novel dosimetry systems based on Al2O3:C radioluminescence (RL) and a 4D dosimetry system (RADPOS) from Best Medical Canada were used to measure the relative output factor (ROF) on Cyberknife. Measurements were performed in a solid water phantom at the depth of 1.5 cm and SSD = 78.5 cm for cones from 5 to 60 mm. ROFs were also measured using a mobileMOSFET system (Best Medical Canada) and EBT1 and EBT2 GAFCHROMIC® (ISP, Ashland) radiochromic films. For cone sizes 12.5–60 mm all detector results were in agreement within the measurement uncertainty. The microMOSFET/RADPOS measurements (published corrections applied) yielded ROFs of 0.650 ± 1.9%, 0.811 ± 0.9% and 0.843 ± 1.7% for the 5, 7.5 and 10 mm cones, respectively, and were in excellent agreement with radiochromic film values (averaged for EBT1 and EBT2) of 0.645 ± 1.4%, 0.806 ± 1.1% and 0.859 ± 1.1%. Monte‐Carlo calculated correction factors were applied to the RL readings to correct for excessive scatter due to the relatively high effective atomic number of Al2O3 (Z=10.2) compared to water for the 5, 7.5 and 10 mm cones. When these corrections are applied to our RL detector measurements, we obtain ROFs of 0.656 ± 0.3% and 0.815 ± 0.3% and 0.865 ± 0.3% for 5, 7.5 and 10 mm cones. Our study shows that the microMOSFET/RADPOS and optical fiber‐coupled RL dosimetry system are well suited for Cyberknife cone output factors measurements over the entire range of field sizes, provided that appropriate correction factors are applied for the smallest cone sizes (5, 7.5 and 10 mm).

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.174
Threshold uncertainty score0.582

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0010.001
Scholarly communication0.0020.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.1740.052

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.034
GPT teacher head0.289
Teacher spread0.254 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".