Planar Drift Tube for Ion Mobility Spectrometry
Bibliographic record
Abstract
The drift tube in ion mobility spectrometry is the component of central importance, where sample vapors are ionized and where ions are separated on the basis of gaseous mobility in a comparatively weak electric field. Construction of drift tubes is labor intensive and costly when built with precision machined components and an alternative design, fabricated using photolithography methods with planar drift plates, is described. Diagnostics of performance including response toward electric fields, peak shape of mobility spectra, determined values for reduced mobility coefficients, and patterns of response to changing vapor concentrations were consistent with conventional drift tubes. Neither ion losses nor band broadening were unexpectedly large though ultimate measures of performance were limited by the unavailability of drift tube components with rectangular profiles and by an imperfect reaction region design. The cost of making drift tubes is calculated as roughly 10% of that for conventional designs.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.001 | 0.001 |
| Meta-epidemiology (narrow) | 0.001 | 0.000 |
| Meta-epidemiology (broad) | 0.001 | 0.000 |
| Bibliometrics | 0.001 | 0.001 |
| Science and technology studies | 0.000 | 0.001 |
| Scholarly communication | 0.001 | 0.001 |
| Open science | 0.002 | 0.001 |
| Research integrity | 0.001 | 0.001 |
| Insufficient payload (model declined to judge) | 0.006 | 0.003 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".