MétaCan
Menu
Back to cohort
Record W2052630208 · doi:10.1055/s-0030-1253167

Biochemical and Physiological MR Imaging of Skeletal Muscle at 7 Tesla and Above

2010· review· en· W2052630208 on OpenAlexaff
Gregory Chang, Ligong Wang, Arturo Cárdenas‐Blanco, Mark E. Schweitzer, Michael P. Recht, Ravinder R. Regatte

Bibliographic record

VenueSeminars in Musculoskeletal Radiology · 2010
Typereview
Languageen
FieldMedicine
TopicAdvanced MRI Techniques and Applications
Canadian institutionsOttawa Hospital
FundersNational Center for Research ResourcesNational Institute of Arthritis and Musculoskeletal and Skin DiseasesRadiological Society of North America
KeywordsMedicineUltra high frequencyNuclear magnetic resonanceMagnetic resonance imagingSkeletal muscleRadiofrequency coilArtifact (error)Magnetic resonance spectroscopic imagingBiomedical engineeringNeuroscienceRadiologyPhysicsAnatomyComputer scienceTelecommunicationsBiology

Abstract

fetched live from OpenAlex

Ultra-high field (UHF; >or=7 T) magnetic resonance imaging (MRI), with its greater signal-to-noise ratio, offers the potential for increased spatial resolution, faster scanning, and, above all, improved biochemical and physiological imaging of skeletal muscle. The increased spectral resolution and greater sensitivity to low-gamma nuclei available at UHF should allow techniques such as (1)H MR spectroscopy (MRS), (31)P MRS, and (23)Na MRI to be more easily implemented. Numerous technical challenges exist in the performance of UHF MRI, including changes in relaxation values, increased chemical shift and susceptibility artifact, radiofrequency (RF) coil design/B (1)(+) field inhomogeneity, and greater RF energy deposition. Nevertheless, the possibility of improved functional and metabolic imaging at UHF will likely drive research efforts in the near future to overcome these challenges and allow studies of human skeletal muscle physiology and pathophysiology to be possible at >or=7 T.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: none
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.004
Threshold uncertainty score0.014

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0020.002
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0040.008

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.019
GPT teacher head0.353
Teacher spread0.334 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designNot applicable
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations14
Published2010
Admission routes1
Has abstractyes

Explore more

Same venueSeminars in Musculoskeletal RadiologySame topicAdvanced MRI Techniques and ApplicationsFrench-language works237,207