Reversed phase capillary HPLC using polymer‐entrapped C18 particles
Bibliographic record
Abstract
Novel capillary columns containing polymer-entrapped octadecylsilyl-modified silica microspheres were evaluated for chromatographic performance. The polymer forms only at the particle surface and in as little as 10 s strongly immobilizes them, obviating the need for a frit. The photoinitiated polymerization is patternable, and various entrapment styles were compared, all of which withstood pressure drops of at least 5000 psi (345 bar). The fritless nature of the columns allows a unique mass production capability whereby long packed columns are entrapped and simply cut afterward. Since the material has previously been shown to be a proficient nanoelectrospray emitter, the columns have enormous potential for use in capillary LC-MS. The evaluation suggests that for the designs that have minimal entrapped regions, the column performance is equivalent to commercial columns containing similar particles.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.001 | 0.001 |
| Meta-epidemiology (narrow) | 0.001 | 0.000 |
| Meta-epidemiology (broad) | 0.001 | 0.000 |
| Bibliometrics | 0.001 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.001 | 0.000 |
| Open science | 0.001 | 0.000 |
| Research integrity | 0.001 | 0.001 |
| Insufficient payload (model declined to judge) | 0.002 | 0.001 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".