MétaCan
Menu
Back to cohort

Design and Fabrication of Novel Compliant Electrostatically Actuated Microvalves

2009· article· en· W2053851605 on OpenAlexaff
Qing Zhang, Nikola Pekas, David Juncker

Bibliographic record

VenueAdvanced materials research · 2009
Typearticle
Languageen
FieldEngineering
TopicMicrofluidic and Capillary Electrophoresis Applications
Canadian institutionsMcGill University
Fundersnot available
KeywordsMicrofabricationFabricationMaterials scienceElectrodeVoltageDie (integrated circuit)Layer (electronics)MicrofluidicsOptoelectronicsNanotechnologyElectrical engineeringEngineering

Abstract

fetched live from OpenAlex

Electrostatically actuated microvalves are appealing candidates to build fully integrated microfluidic circuits because of the direct transduction of electrical signals into mechanical responses at low power consumption levels. Practical solutions, however, are still lacking due to their multi-layered architecture and difficulties in incorporating heterogeneous materials. In this paper, we report the design and fabrication process of an electrostatically actuated gas microvalve amenable to large scale integration for gas flow control. The device we designed consists of an upper die, containing a flexible electrode sealed by a thin elastic membrane, and a lower die, containing gas channels of trapezoidal cross-section and fixed electrodes. Each microvalve is defined by one fixed electrode spanning the floor and sidewalls of the trapezoidal gas channel and one corresponding flexible electrode suspended above the channel. In contrast to the conventional parallel-plate arrangement of electrodes, the two electrodes are approximated starting from the edges of the trapezoidal gas channel during the actuation step, which is advantageous for lowering the required actuation voltage. The upper die was fabricated by replica molding in polymeric material, the lower die was fabricated in a glass substrate by conventional microfabrication techniques, and the two dies were subsequently aligned and bonded using an adhesive layer. This reported low cost fabrication process could be implemented in any basic microfabrication facility. When a net pressure up to 1 bar was applied to the gas channel, reasonable flow rate was achieved. We also observed displacement of the flexible membrane when a DC voltage of 200 V was applied to a pair of electrodes. These preliminary results show that this microvalve is a promising candidate for integrated on-chip valving and will allow for building large scale microfluidic circuits with reduced power consumption.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.140
Threshold uncertainty score0.376

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.036
GPT teacher head0.318
Teacher spread0.282 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2009
Admission routes1
Has abstractyes

Explore more

Same venueAdvanced materials researchSame topicMicrofluidic and Capillary Electrophoresis ApplicationsFrench-language works237,207