MétaCan
Menu
Back to cohort
Record W2053945486 · doi:10.1016/s0886-3350(02)01325-1

Ultrasound biomicroscopy of the Artisan phakic intraocular lens in hyperopic eyes

2002· article· en· W2053945486 on OpenAlexaff
Mihai Pop, Yves Payette, Magdi Mansour

Bibliographic record

VenueJournal of Cataract & Refractive Surgery · 2002
Typearticle
Languageen
FieldMedicine
TopicIntraocular Surgery and Lenses
Canadian institutionsSTART Clinic
Fundersnot available
KeywordsUltrasound biomicroscopyMedicineOphthalmologyIntraocular lensIRIS (biosensor)GonioscopyCorneal endotheliumDioptrePhakic intraocular lensLens (geology)Intraocular pressureCorneaGlaucomaRefractive errorEye diseaseVisual acuityOptics

Abstract

fetched live from OpenAlex

PURPOSE: To study in situ the intraocular position of the Artisan iris-claw intraocular lens (IOL) (model 203) (Ophtec) in phakic hyperopic eyes using ultrasound biomicroscopy (UBM). METHODS: Echograms of the anterior chamber were taken preoperatively and 24 to 317 days postoperatively in 4 eyes implanted with the Artisan IOL (power +4.0 to +6.0 diopters). The preoperative anterior chamber depth (ACD) and the postoperative distance between the IOL and the corneal endothelium (endothelium-optic distance) and between the IOL and the lens were measured. The echograms were assessed for the effect of the IOL on iris tissue. RESULTS: The preoperative ACD ranged from 3.10 to 3.56 mm and the postoperative endothelium-optic distance, from 2.03 to 2.54 mm. The distance between the lens and the posterior surface of the IOL ranged from 0.35 to 0.79 mm. Several UBM echograms showed indentation of iris tissue by the IOL haptics and optic edge, although no pigmentary dispersion was noted. CONCLUSIONS: Adequate space was maintained between the Artisan hyperopic IOL and the corneal endothelium, angle, and crystalline lens. Haptic indentation of the iris, which could lead to pigment erosion, was observed. Preoperative gonioscopy and maintenance of normal intraocular pressure postoperatively suggest the indentation was secondary to inadequate lens vaulting relative to the high natural arch of the iris in hyperopic eyes. Shortening the haptics or increasing the lens vault might resolve this problem.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.027
GPT teacher head0.257
Teacher spread0.230 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations28
Published2002
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Cataract & Refractive SurgerySame topicIntraocular Surgery and LensesFrench-language works237,207