MétaCan
Menu
Back to cohort
Record W2054166018 · doi:10.3109/02713683.2012.682636

Using an<i>In Vitro</i>Model of Lipid Deposition to Assess the Efficiency of Hydrogen Peroxide Solutions to Remove Lipid from Various Contact Lens Materials

2012· article· en· W2054166018 on OpenAlexaff
Holly Lorentz, Miriam Heynen, Helen Tran, Lyndon Jones

Bibliographic record

VenueCurrent Eye Research · 2012
Typearticle
Languageen
FieldMedicine
TopicOcular Surface and Contact Lens
Canadian institutionsUniversity of Waterloo
Fundersnot available
KeywordsHydrogen peroxidePulmonary surfactantChemistryChromatographyContact lensPhosphatidylcholinePeroxideNuclear chemistryOrganic chemistryBiochemistryPhospholipidMembrane

Abstract

fetched live from OpenAlex

PURPOSE: To test the ability of two commercially available hydrogen peroxide disinfection solutions, one containing a surfactant and one without, to remove lipid from various contact lens materials using in vitro radiochemical experiments. METHODS: Etafilcon A, senofilcon A and balafilcon A contact lens materials were incubated in an artificial tear solution (ATS) containing a mixture of lipids, proteins, mucin and either (14)C-cholesterol or (14)C-phosphatidylcholine for 8 h. Following incubation, the lenses were removed, rinsed, and placed for 16 h in either a surfactant-containing peroxide solution (ClearCare®), a peroxide solution devoid of a surfactant (AOSept®) or stored without solution (control). This process was repeated every day for 1 week. The lenses were extracted with a previously optimized extraction protocol, evaporated, re-suspended, fluor added and counted for their radioactive signals. Masses of lipids deposited were calculated based on standard calibration curves, the disinfection solutions were compared and repeated measures ANOVA and post hoc statistical analysis was completed using Statistica 9. RESULTS: The results of this experiment found that daily disinfection with hydrogen peroxide solutions reduced the amount of cholesterol and phosphatidylcholine deposited on the three contact lens materials examined, however in many cases the reduction in deposition was less than 15% when compared to the control. Disinfection with the solution containing the surfactant (ClearCare), resulted in the least deposited cholesterol and phosphatidylcholine for all materials, however not all of the comparisons were statistically significant. CONCLUSIONS: Overall, ClearCare hydrogen peroxide disinfection solution containing Pluronic 17R4 removed the most lipid from lenses when compared to the non-surfactant containing AOSept or the control, for both lipids and all lens materials. However, the differences found were quite small at times and whether these differences are clinically significant are yet to be determined.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.005

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.231
GPT teacher head0.423
Teacher spread0.192 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations18
Published2012
Admission routes1
Has abstractyes

Explore more

Same venueCurrent Eye ResearchSame topicOcular Surface and Contact LensFrench-language works237,207