Bibliographic record
Abstract
Previous study of a microturbine-based combined heat, cooling and power system installed on a university campus showed that the turbine exhaust energy must be fully utilized for the economics to be favorable. The system studied combined four 60 kW microturbines with a 110 ton absorption chiller that recovers exhaust waste heat. The chiller, which has the capability of providing either chilled water for cooling or hot water for heating depending on seasonal needs, was found to be mismatched to the local heating and cooling needs. This paper describes the design of an exhaust heat exchanger that will be integrated into the campus steam plant for more efficient utilization of the microturbine waste heat. The hot water generated will be used during heating season to heat a nearby building with a hydronic heating system. This will reduce boiler fuel costs, since this heating load would otherwise be met from a steam heating station. At other times of the year, the hot water generated will be used to preheat condensate return for the campus steam plant, which has a year-round steam demand.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.001 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.005 | 0.001 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".