MétaCan
Menu
Back to cohort
Record W2054568763 · doi:10.1088/0031-9155/57/10/3155

An x-ray CT polymer gel dosimetry prototype: II. Gel characterization and clinical application

2012· article· en· W2054568763 on OpenAlexaff
H Johnston, Michelle Hilts, Jennifer Carrick, Andrew Jirasek

Bibliographic record

VenuePhysics in Medicine and Biology · 2012
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsBC Cancer AgencyUniversity of Victoria
Fundersnot available
KeywordsDosimeterReproducibilityMaterials scienceCalibrationDosimetryIrradiationCalibration curveNuclear medicinePixelPolymerBiomedical engineeringOpticsMedicineChromatographyChemistryPhysicsComposite materialDetection limit

Abstract

fetched live from OpenAlex

This article reports on the dosimetric properties of a new N-isopropylacrylamide, high %T, polymer gel formulation (19.5%T, 23%C), optimized for x-ray computed tomography (CT) polymer gel dosimetry (PGD). In addition, a new gel calibration technique is introduced together with an intensity-modulated radiation therapy (IMRT) treatment validation as an example of a clinical application of the new gel dosimeter. The dosimetric properties investigated include the temporal stability, spatial stability, batch reproducibility and dose rate dependence. The polymerization reaction is found to stabilize after 15 h post-irradiation. Spatial stability investigations reveal a small overshoot in response for gels imaged later than 36 h post-irradiation. Based on these findings, it is recommended that the new gel formulation be imaged between 15-36 h after irradiation. Intra- and inter-batch reproducibility are found to be excellent over the entire range of doses studied (0-28 Gy). A significant dose rate dependence is found for gels irradiated between 100-600 MU min⁻¹. Overall, the new gel is shown to have promising characteristics for CT PGD, however the implication of the observed dose rate dependence for some clinical applications remains to be determined. The new gel calibration method, based on pixel-by-pixel matching of dose and measured CT numbers, is found to be robust and to agree with the previously used region of interest technique. Pixel-by-pixel calibration is the new recommended standard for CT PGD. The dose resolution for the system was excellent, ranging from 0.2-0.5 Gy for doses between 0-20 Gy and 0.3-0.6 Gy for doses beyond 20 Gy. Comparison of the IMRT irradiation with planned doses yields excellent results: gamma pass rate (3%, 3 mm) of 99.3% at the isocentre slice and 93.4% over the entire treated volume.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.005

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.069
GPT teacher head0.423
Teacher spread0.354 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations57
Published2012
Admission routes1
Has abstractyes

Explore more

Same venuePhysics in Medicine and BiologySame topicAdvanced Radiotherapy TechniquesFrench-language works237,207