MétaCan
Menu
Back to cohort
Record W2055094789 · doi:10.1177/0954411912450998

Biomechanical measurements of cortical screw stripping torque in human versus artificial femurs

2012· article· en· W2055094789 on OpenAlexaff
Bruce Nicayenzi, Meghan Crookshank, Michael Olsen, Emil H. Schemitsch, Habiba Bougherara, Rad Zdero

Bibliographic record

VenueProceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · 2012
Typearticle
Languageen
FieldMedicine
TopicHip and Femur Fractures
Canadian institutionsUniversity of TorontoToronto Metropolitan UniversitySt. Michael's Hospital
Fundersnot available
KeywordsStripping (fiber)FemurCortical boneBiomedical engineeringTorqueBone mineralMaterials scienceHuman boneArtificial boneAnatomyNuclear medicineMedicineChemistrySurgeryPhysicsOsteoporosisPathologyComposite material

Abstract

fetched live from OpenAlex

Femur fracture plates are applied using cortical bone screws. Surgeons do this manually by subjective 'feel' without monitoring torque. Few studies have quantified stripping torque in human bone. No studies have measured stripping torque in the artificial bones from Sawbones (Vashon, WA, USA) that are frequently used in biomechanical studies. The present aim was to measure stripping torque of cortical screws in human versus artificial femurs. Sixteen fresh-frozen human femurs and eight artificial femurs were used. Using a digital torque screwdriver, each femur had a 3.5-mm diameter uni-cortical screw manually inserted into the anterior midshaft until failure of the screw-bone interface. Results were normalized by cortical thickness and the screw-bone interfacial area. There were no statistical differences in human versus artificial data, respectively, for stripping torque (1741 +/- 442 N.mm, 2012 +/- 176 N.mm, p = 0.11), stripping torque/thickness (313 +/- 59 N, 305 +/- 30 N, p = 0.74), and stripping torque area (28.5 +/- 5.3 N/mm, 27.8 +/- 2.8 N/mm, p = 0.74). Artificial unicortical thickness (6.6 + 0.3 mm) was greater than human thickness (5.6 +/- 1.1 mm) (p = 0.02). For human specimens, there was a moderate linear correlation of absolute and normalized stripping torque versus standardized bone mineral density (R > or = 0.32) and clinical T-score (R = 0.29), but not with age (R < or = 0.29). Surgeons should be aware of the stripping torque limits for human femurs and potentially take steps to monitor these values during surgery. The artificial femurs being increasingly used in research accurately replicate human cortical properties during screw insertion. To date, this is the first series of human femurs evaluated for cortical screw stripping.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.005
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.019
Threshold uncertainty score0.608

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.005
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.069
GPT teacher head0.312
Teacher spread0.243 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations17
Published2012
Admission routes1
Has abstractyes

Explore more

Same venueProceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in MedicineSame topicHip and Femur FracturesFrench-language works237,207