MétaCan
Menu
← Back to cohort
Record W2056140387 · doi:10.1118/1.4735615

SU‐E‐T‐526: Evaluation of Dose Mapping Errors via Use of a Volume‐Based Dose Mapping Method

2012· article· en· W2056140387 on OpenAlexaff
H Chen, N.K. Saleh-Sayah, W.T. Watkins, C. Yan, Francisco J. Salguero, Emily Heath, Jeffrey V. Siebers

Bibliographic record

VenueMedical Physics · 2012
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsToronto Metropolitan University
Fundersnot available
KeywordsPinnacleVoxelNuclear medicineVolume (thermodynamics)Range (aeronautics)DosimetryPhysicsMaterials scienceComputer scienceMedicineRadiation therapyRadiation treatment planningArtificial intelligenceRadiology

Abstract

fetched live from OpenAlex

PURPOSE: To quantify dose mapping errors (DMEs) of a point-based dose mapping method for 4D lung treatment plans. METHODS: Point-based dose mapping methods utilize deformation vector fields (DVFS) to interpolate dose from a deformed image. Volume-based dose mapping methods consider the volume overlap between deformed and reference voxels; defining dose as the integral energy divided by the integral mass of the voxel, and conserving integral dose . DME is defined as the dose differences between volume-based and point-based mapped dose (DME=(DpointBased-DvolumeBased)/DRx). The DME for a 4D lung case is compared with a bitmap DME method, both using a Pinnacle research version 8.1y DVF. DME is computed for ten 4D lung cases (five 10 phases, five 3 phase) with Pinnacle research version 9.100 DVFs. Multi-phase accumulated 4D DMEs are also evaluated. RESULTS: For all cases, the largest DMEs are located in the dose/density gradient regions. With Pinnacle 8.1y DVF, mapping dose from phase 9 to phase 0, results in a DME=-0.2%±6.1% (range of -76%∼112%). The same case with Pinnacle 9.100 DVFs, DME=0.3%±4.8%(-41%∼32%). Locations of large DME are consistent with those from the bitmap method. For the ten 4D lung cases, accumulated mean DME are within ±0.07% (std. deviations: 1∼5%, range -102%∼64%). Maximum tumor DMEs are less than 30cGy (DRx=7200cGy) for all patients. CONCLUSIONS: Due to its inherent integral dose conservation, volume-based dose mapping methods can quantify errors in point-based dose mapping methods. While mean DME values are small for the cases tested, standard deviations near 5% indicate that a substantial number of voxels have ∼5% dose mapping errors, however these dose errors do not occur in the target structures. Work supported by NIH P01CA116602.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.008
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.011

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.008
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0030.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.072
GPT teacher head0.368
Teacher spread0.296 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2012
Admission routes1
Has abstractyes

Explore more

Same venueMedical Physics→Same topicAdvanced Radiotherapy Techniques→French-language works237,207→