MétaCan
Menu
Back to cohort
Record W2056511666 · doi:10.1088/0967-3334/25/1/003

Three-dimensional visualization and thickness estimation of aortic valve cusps using high-frequency ultrasound

2003· article· en· W2056511666 on OpenAlexafffund
James C. Lacefield, Jeff Weaver, Jack R Spence, Joy Dunmore‐Buyze, Derek R. Boughner

Bibliographic record

VenuePhysiological Measurement · 2003
Typearticle
Languageen
FieldMedicine
TopicCardiac Valve Diseases and Treatments
Canadian institutionsLondon Health Sciences CentreRobarts Clinical TrialsWestern University
FundersCanada Research ChairsOntario Innovation Trust
KeywordsUltrasoundVolume (thermodynamics)Distilled waterBiomedical engineeringHigh frequency ultrasoundMaterials scienceAortic valveHeart valveMedicineRadiologyChemistryCardiologyPhysics

Abstract

fetched live from OpenAlex

High-frequency ultrasound techniques are introduced for three-dimensional imaging and thickness estimation of fresh heart valve cusps. Images of porcine aortic valve specimens were acquired within a 12 x 8 x 8 mm3 volume using a VisualSonics VS40 micro-imaging system operating at a 40 MHz centre frequency. Two image volumes were obtained from each of six left coronary cusps. One volume was acquired with the specimen submerged in distilled water and the second volume was acquired through either Hanks physiologic solution or coronary perfusion solution (CPS). The fibrosa, spongiosa and ventricularis were most readily distinguished when the specimen was imaged in distilled water. Colour thickness maps were computed from B-mode image data, and the mean and standard deviations of the thickness were determined for each cusp. In 11 of 12 trials, the image analysis algorithm yielded valid thickness estimates over greater than 98% of the region examined. Mean thickness estimates obtained with specimens submerged in Hanks solution or CPS ranged from 0.66 to 1.03 mm, and submersion in distilled water increased the mean thickness by 20-40%. This observation suggests that the cusps osmotically absorbed water. Information provided by high-frequency ultrasound is expected be valuable for characterizing the morphological properties of heart valves.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.719
Threshold uncertainty score0.423

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.065
GPT teacher head0.345
Teacher spread0.279 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations10
Published2003
Admission routes2
Has abstractyes

Explore more

Same venuePhysiological MeasurementSame topicCardiac Valve Diseases and TreatmentsFrench-language works237,207