MétaCan
Menu
Back to cohort

Predictors and Clinical Impact of Atrial Fibrillation After Pacemaker Implantation in Elderly Patients Treated with Dual Chamber Versus Ventricular Pacing

2003· article· en· W2057230422 on OpenAlexaff
Bruce S. Stambler, Kenneth A. Ellenbogen, E. John Orav, Elena B. Sgarbossa, N.A. Mark Estes, Carlos Rizo-Patrón, James B. Kirchhoffer, Tom Hadjis, Lee Goldman, Gervasio A. Lamas

Bibliographic record

VenuePacing and Clinical Electrophysiology · 2003
Typearticle
Languageen
FieldMedicine
TopicCardiac pacing and defibrillation studies
Canadian institutionsMontreal General Hospital
Fundersnot available
KeywordsMedicineAtrial fibrillationCardiologyInternal medicineArtificial cardiac pacemakerRandomizationSick sinus syndromeBradycardiaHeart failureProportional hazards modelProspective cohort studyRandomized controlled trialHeart rateBlood pressure

Abstract

fetched live from OpenAlex

The Pacemaker Selection in the Elderly (PASE) trial was a prospective, multicenter, single blind, randomized comparison of single chamber, rate adaptive, ventricular pacing (VVIR) with dual chamber, rate adaptive pacing (DDDR) in 407 patients aged > or =65 years(mean 76 +/- 7 years, 60% male)with standard bradycardia indications for dual chamber pacemaker implantation. The incidence, predictors, and clinical consequences of atrial fibrillation (AF) developing after pacemaker implantation in the PASE trial were studied prospectively. During a median follow-up of 18 months, AF developed in 73 (18%) patients. Kaplan-Meier estimated cumulative incidences of AF in patients with sinus node dysfunction (n=176) at 18 months were 28% in the VVIR and 16% in the DDDR groups (P=0.08). After adjustment for other clinical variables using a Cox multivariate regression model, randomization to VVIR compared with DDDR pacing mode among patients with sinus node dysfunction was independently associated with a 2.6-fold increased relative risk (RR) of developing AF after pacemaker implantation (P=0.01). Other independent clinical risk factors for development of postimplant AF included a preimplant history of hypertension (P=0.02) or supraventricular tachyarrhythmias(P<0.04). Patients who developed AF had similar health related quality of life scores and cardiovascular functional status after 18 months of pacing as patients who remained free of AF. The RR of death, stroke, or heart failure hospitalization was not increased in patients who developed AF. Thus, in the elderly patients with sinus node dysfunction requiring permanent pacing, DDDR pacing mode protected against the development of AF. However, development of AF after pacemaker implantation in this population was not associated with a significant impact on quality-of-life, functional status, or other clinical endpoints during 18 months of follow-up.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.010
Threshold uncertainty score0.561

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.017
GPT teacher head0.335
Teacher spread0.318 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations49
Published2003
Admission routes1
Has abstractyes

Explore more

Same venuePacing and Clinical ElectrophysiologySame topicCardiac pacing and defibrillation studiesFrench-language works237,207