Metal-on-Metal Hybrid Surface Arthroplasty
Bibliographic record
Abstract
BACKGROUND: Following the reintroduction of metal-on-metal articulating surfaces for total hip arthroplasty in Europe in 1988, we developed a surface arthroplasty prosthetic system using a metal-on-metal articulation. The present study describes the clinical and radiographic results of the first 400 hips treated with metal-on-metal hybrid surface arthroplasties at an average follow-up of three and a half years. METHODS: Between November 1996 and November 2000, 400 metal-on-metal hybrid surface arthroplasties were performed in 355 patients. All femoral head components were cemented, but only fifty-nine of the short metaphyseal stems were cemented. The patients had an average age of forty-eight years, 73% were men, and 66% had a diagnosis of osteoarthritis. Clinical and radiographic follow-up was performed at three months postoperatively and yearly thereafter. RESULTS: The majority of the patients returned to a high level of activity, including sports, and 54% had activity scores of >7 on the University of California at Los Angeles activity assessment system. Kaplan-Meier survivorship curves demonstrated that the rate of survival of the components at four years was 94.4%. For patients with a surface arthroplasty risk index score of >3, the rate of survival of the components at four years was 89% compared with a rate of 97% for those with a score of <or=3. The patients with a higher risk index were 4.2 times more likely to undergo revision to a total hip replacement at four years. Twelve hips (3%) had a revision to a total hip replacement. Seven of the twelve hips were revised because of loosening of the femoral component, and three were revised because of a femoral neck fracture. Substantial radiolucencies were seen around sixteen uncemented metaphyseal femoral stems. No femoral radiolucencies were observed among the hips in which the metaphyseal stem was cemented. The most important risk factors for femoral component loosening and substantial stem radiolucencies were large femoral head cysts (p = 0.029), patient height (p = 0.032), female gender (p = 0.005), and smaller component size in male patients (p = 0.005). CONCLUSIONS: The preliminary experience with this hybrid metal-on-metal bearing is encouraging. Optimal femoral bone preparation and component fixation are critical to improving durability. The metal-on-metal hybrid surface arthroplasty is easily revised to a standard femoral component if necessary.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.001 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.001 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".