MétaCan
Menu
Back to cohort
Record W2058785810 · doi:10.2214/ajr.12.10513

Hybrid Iterative Reconstruction Technique for Abdominal CT Protocols in Obese Patients: Assessment of Image Quality, Radiation Dose, and Low-Contrast Detectability in a Phantom

2014· article· en· W2058785810 on OpenAlexaff
Sebastian T. Schindera, Devang Odedra, Diego Mercer, Seng Thipphavong, Paul B. Chou, Zsolt Szucs‐Farkas, Patrik Rogalla

Bibliographic record

VenueAmerican Journal of Roentgenology · 2014
Typearticle
Languageen
FieldMedicine
TopicRadiation Dose and Imaging
Canadian institutionsUniversity of TorontoUniversity Health Network
Fundersnot available
KeywordsImaging phantomMedicineImage noiseImage qualityContrast-to-noise ratioNoise (video)Nuclear medicineAbdominal computed tomographyNoise reductionContrast (vision)Iterative reconstructionRadiologyPhysicsImage (mathematics)OpticsArtificial intelligenceComputer science

Abstract

fetched live from OpenAlex

OBJECTIVE: The purpose of this study was to assess the impact of a noise reduction technique on image quality, radiation dose, and low-contrast detectability in abdominal CT for obese patients. MATERIALS AND METHODS: A liver phantom with 12 different tumors was designed, and fat rings were added to mimic intermediately sized and large patients. The intermediate and large phantoms were scanned with our standard abdominal CT protocol (image noise level of 15 HU and filtered back projection [FBP]). The large phantom was scanned with five different noise levels (10, 12.5, 15, 17.5, and 20 HU). All datasets for the large phantom were reconstructed with FBP and the noise reduction technique. The image noise and the contrast-to-noise ratio (CNR) were assessed. Tumor detection was independently performed by three radiologists in a blinded fashion. RESULTS: The application of the noise reduction method to the large phantom decreased the measured image noise (range, -14.5% to -37.0%) and increased the CNR (range, 26.7-70.6%) compared with FBP at the same noise level (p < 0.001). However, noise reduction was unable to improve the sensitivity for tumor detection in the large phantom compared with FBP at the same noise level (p > 0.05). Applying a noise level of 15 HU, the overall sensitivity for tumor detection in the intermediate and large phantoms with FBP measured 75.5% and 87.7% and the radiation doses measured 42.0 and 23.7 mGy, respectively. CONCLUSION: Although noise reduction significantly improved the quantitative image quality in simulated large patients undergoing abdominal CT compared with FBP, no improvement was observed for low-contrast detectability.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.309
Threshold uncertainty score0.393

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.009
GPT teacher head0.348
Teacher spread0.339 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations40
Published2014
Admission routes1
Has abstractyes

Explore more

Same venueAmerican Journal of RoentgenologySame topicRadiation Dose and ImagingFrench-language works237,207