Effect of Electrode Geometry on Droplet Splitting in Digital Microfluidic Platforms
Bibliographic record
Abstract
This paper studies the effect of the electrode aspect ratio on droplet splitting in a digital microfluidics (DMF) chip including an array of 3 electrodes in which the middle electrode is kept square while the two side electrodes have different aspect ratios. The aspect ratio is changed from 0.9 to 1.3 while the surface area of the electrodes is kept constant for all cases. Results show that changing the aspect ratio can severely change the required voltage for splitting with a nonlinear behavior. It is also shown that for a constant gap between the top and bottom plates and a constant volume of the droplet, the relation between the threshold voltage and the aspect ratio is parabolic, for which there is an aspect ratio with a minimum threshold voltage. Changing the volume of the droplet changes the threshold voltage and hence the aspect ratio corresponding to the minimum threshold voltage required for splitting.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".