MétaCan
Menu
Back to cohort
Record W2059189228 · doi:10.1002/mrm.21132

Partial <i>k</i>‐space reconstruction in single‐shot diffusion‐weighted echo‐planar imaging

2007· article· en· W2059189228 on OpenAlexafffund
Pippa Storey, Fred J. Frigo, R. Scott Hinks, Bryan J. Mock, B. Collick, Nicole Baker, Jonathan Marmurek, Simon J. Graham

Bibliographic record

VenueMagnetic Resonance in Medicine · 2007
Typearticle
Languageen
FieldMedicine
TopicAdvanced Neuroimaging Techniques and Applications
Canadian institutionsUniversity of TorontoHealth Sciences CentreSunnybrook Health Science Centre
FundersNatural Sciences and Engineering Research Council of Canada
KeywordsEcho (communications protocol)Direct-conversion receiverk-spacePhysicsArtifact (error)PlanarEcho-planar imagingSampling (signal processing)Truncation (statistics)Homodyne detectionNuclear magnetic resonanceOpticsComputer visionComputer scienceMagnetic resonance imagingFourier transformDetector

Abstract

fetched live from OpenAlex

Partial k-space sampling is frequently used in single-shot diffusion-weighted echo-planar imaging (DW-EPI) to reduce the TE and thereby improve the SNR. However, it increases the sensitivity of the technique to bulk rotational motion, which introduces a phase gradient across the tissue that shifts the echo in k-space. If the echo is displaced into the high spatial frequencies, conventional homodyne reconstruction fails, causing intensity oscillations across the image. Zero-padding, on the other hand, compromises the image resolution and may cause truncation artifacts. We present an adaptive version of the homodyne algorithm that detects the location of the echo in k-space and adjusts the center and width of the homodyne filters accordingly. The adaptive algorithm produces artifact-free images when the echo is shifted into the high positive k-space range, and reduces to the standard homodyne algorithm in the absence of bulk motion.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Methods · Consensus signal: Methods
Teacher disagreement score0.002
Threshold uncertainty score0.005

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0000.001
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.042
GPT teacher head0.329
Teacher spread0.287 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations49
Published2007
Admission routes2
Has abstractyes

Explore more

Same venueMagnetic Resonance in MedicineSame topicAdvanced Neuroimaging Techniques and ApplicationsFrench-language works237,207