MétaCan
Menu
← Back to cohort

Six years of experience with nightly home hemodialysis access

2004· article· en· W2059288121 on OpenAlexvenueno aff
Mary Pipkin, Viola Craft, Maureen Spencer, Robert S. Lockridge

Bibliographic record

VenueHemodialysis International · 2004
Typearticle
Languageen
FieldMedicine
TopicDialysis and Renal Disease Management
Canadian institutionsnot available
Fundersnot available
KeywordsMedicineCatheterHemodialysisSurgerySepsisDialysis catheterFistulaHemodialysis CatheterCannulaExit siteDialysisArteriovenous fistula

Abstract

fetched live from OpenAlex

BACKGROUND: Lynchburg Nephrology Dialysis Incorporated started its nightly home hemodialysis (NHHD) program in September 1997. PURPOSE: The purpose of this study was to evaluate episodes of exit-site infections, catheter sepsis, and safety and longevity of accesses for patients doing NHHD. METHOD: If internal jugular (IJ) catheter was chosen, the patient was started on 2 mg coumadin per day when catheter was placed. If catheter malfunctioned, it was blocked with a thrombolytic agent and coumadin was adjusted to meet a goal international normalized ratio (INR) of 1.5 to 2.25. If the problem persisted, the catheter was exchanged. For catheters, a threaded lock cannula (BD InterLink device, BD) was used to prevent air emboli and infections and a locking device was used to prevent disconnects. If arteriovenous (AV) fistula was used, four buttonholes were established using 16-gauge needles. If AV graft was used, patients were taught the rope ladder cannulation technique using 16-gauge needles. RESULTS: As of September 1, 2003, 45 patients have completed training and have performed 27,063 treatments at home. Total catheter time at home was 930 months. Total AV fistula and AV graft times at home were 190 and 20 months, respectively. Upon completion of training, 34 patients were using tunneled IJ catheters, 10 were using AV fistulas, and 1 was using an AV graft. The IJ catheter exit-site and sepsis infection rates were 0.35 and 0.52 episodes per 1000 patient-days, respectively. Mean catheter life was 8.5 months with the longest being 66.7 months and the shortest being 0.2 months. The AV fistula and graft exit-site and sepsis infection rates were 0.16 and 0 episodes per 1000 patient-days, respectively. Catheter complications included one episode of disconnect due to patient's failure to use the locking device, one episode of central stenosis, and one episode of intracranial hemorrhage, due to prolonged INR, with resolution of symptoms. CONCLUSION: Data support the fact that tunneled IJ catheters, AV fistulas, and AV grafts are effective and safe permanent accesses for patients on NHHD.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.007
Threshold uncertainty score0.025

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0010.000
Scholarly communication0.0010.001
Open science0.0000.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0070.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.017
GPT teacher head0.290
Teacher spread0.274 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations23
Published2004
Admission routes1
Has abstractyes

Explore more

Same venueHemodialysis International→Same topicDialysis and Renal Disease Management→French-language works237,207→