MétaCan
Menu
Back to cohort

Assessment of Resynchronization Therapy on Functional Status and Quality of Life in Patients Requiring an Implantable Defibrillator

2009· article· en· W2059439433 on OpenAlexaff
Arnold Pintér, Iqwal Mangat, Victoria Korley, Stuart J. Connolly, Sean P. Connors, Martin J. Gardner, François Philippon, Larry Sterns, Bernard Thibault, Paul Dorian

Bibliographic record

VenuePacing and Clinical Electrophysiology · 2009
Typearticle
Languageen
FieldMedicine
TopicCardiac pacing and defibrillation studies
Canadian institutionsMontreal Heart InstituteUniversity of TorontoDalhousie UniversityMemorial University of NewfoundlandMcMaster UniversitySt. Michael's Hospital
Fundersnot available
KeywordsMedicineCardiac resynchronization therapyHeart failureEjection fractionCardiologyInternal medicineQuality of life (healthcare)Clinical endpointQRS complexImplantable cardioverter-defibrillatorRandomized controlled trialGuidelinePopulation

Abstract

fetched live from OpenAlex

BACKGROUND: The effect of cardiac resynchronization therapy (CRT) on physical function and Quality of Life (QoL) in patients who require an implantable defibrillator but do not meet guideline criteria for CRT has not been studied in detail. METHODS AND RESULTS: This was a randomized study of 72 patients with high risk of sudden cardiac death, ejection fraction (EF) < or =35%, mild-to-moderate heart failure symptoms, and QRS > 120 ms. Patients received a CRT defibrillator and were randomized to CRT turned ON or OFF. Objective and subjective measures were performed at baseline and after 6 months. There was no difference in change in left ventricular end-systolic volume (ESV) by radionuclid angiogram scan, the primary endpoint, between the CRT ON group (DeltaESV =-7 +/- 52 mL), and CRT OFF group (DeltaESV =-30 +/- 47 mL). Similarly, echocardiogram measures of ESV and EF showed no difference between the two groups. In the CRT ON group, selected measures of QoL and subjective exercise tolerance but not heart failure symptoms improved significantly. Six-minute walk distance prolonged in the CRT ON group (baseline 313.6 +/- 114.4 m, 6-month 365.0 +/- 122.5 m, P = 0.01), but the difference in change in walk distance between the two groups was not significant. CONCLUSION: Further studies with larger sample size and longer follow-up will be required to allow definite conclusions regarding the potential benefit of CRT in this patient population.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.015
Threshold uncertainty score0.285

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.060
GPT teacher head0.398
Teacher spread0.339 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations10
Published2009
Admission routes1
Has abstractyes

Explore more

Same venuePacing and Clinical ElectrophysiologySame topicCardiac pacing and defibrillation studiesFrench-language works237,207