MétaCan
Menu
Back to cohort
Record W2059773750 · doi:10.1118/1.4814930

SU‐E‐T‐501: A Sensitivity Study of Tissue Characterization for Brachytherapy Monte Carlo Dose Calculation

2013· article· en· W2059773750 on OpenAlexaff
Stéphane Bedwani, Jean‐François Carrier, Hugo Bouchard

Bibliographic record

VenueMedical Physics · 2013
Typearticle
Languageen
FieldEngineering
TopicAdvanced X-ray and CT Imaging
Canadian institutionsCentre Hospitalier de l’Université de MontréalUniversité de Montréal
Fundersnot available
KeywordsMonte Carlo methodBrachytherapyHounsfield scaleIntersection (aeronautics)Nuclear medicineMathematicsDosimetryAlgorithmPhysicsStatisticsMedicineComputed tomographyRadiation therapy

Abstract

fetched live from OpenAlex

Purpose: To establish the reliability of electron density (ED) mapping and tissue segmentation techniques using CT images for brachytherapy, considering stochastic and systematic Hounsfield unit (HU) variations. Methods: Most common artifacts are simulated within a Monte Carlo theoretical framework. A set of CT data is first generated with the EGSnrc suite followed by their reconstruction performed with an iterative algorithm. A statistical analysis of HU values from reconstructed images is performed to determine uncertainties and systematic effects introduced by the iterative algorithm and the presence of artifacts. Maps of ED and tissue indexes are retrieved from an HU‐ED curve calibrated at 120 kVp using experimental measurements and ICRU data. The mean energy absorption coefficient for each tissue is computed from ICRU data for an Iridium‐192 source in order to evaluate the impact on dose calculations. A probabilistic approach is used to compute the uncertainty on absorbed dose generating random distributions of HU and determining the probabilistic effects on the extracted ED and absorption coefficients. Results: For an uncertainty of +/− 20 HU, absorption coefficient uncertainties raise up to 3% when HU values are near the fat‐muscle intersection and up to 9% near the muscle‐spongiosa intersection. Uncertainties on ED are found to be less than 1% for HU above 0 and up to 3% for fat. A systematic effect of 50 HU caused by typical artifacts yields absorption coefficient errors up to 30% for HU values near the muscle‐spongiosa region, and errors in ED up to 8% for fat. Conclusion: Results show that the main source of dose calculation uncertainty is caused by the sensitivity of the tissue segmentation technique. This study suggests that improvements in such techniques are yet to be achieved.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.855
Threshold uncertainty score0.412

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.010
GPT teacher head0.255
Teacher spread0.245 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2013
Admission routes1
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicAdvanced X-ray and CT ImagingFrench-language works237,207