MétaCan
Menu
← Back to cohort
Record W2061867820 · doi:10.1117/12.2043066

Assessing and improving cobalt-60 digital tomosynthesis image quality

2014· article· en· W2061867820 on OpenAlexaff
M Marsh, L J Schreiner, A Kerr

Bibliographic record

VenueProceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · 2014
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsQueen's University
Fundersnot available
KeywordsTomosynthesisFiducial markerComputer scienceImage qualityModality (human–computer interaction)Cone beam computed tomographyIterative reconstructionImage resolutionNuclear medicineMedical imagingOpticsArtificial intelligencePhysicsComputer visionMedicineRadiologyImage (mathematics)MammographyComputed tomography

Abstract

fetched live from OpenAlex

Image guidance capability is an important feature of modern radiotherapy linacs, and future cobalt-60 units will be expected to have similar capabilities. Imaging with the treatment beam is an appealing option, for reasons of simplicity and cost, but the dose needed to produce cone beam CT (CBCT) images in a Co-60 treatment beam is too high for this modality to be clinically useful. Digital tomosynthesis (DT) offers a quasi-3D image, of sufficient quality to identify bony anatomy or fiducial markers, while delivering a much lower dose than CBCT. A series of experiments were conducted on a prototype Co-60 cone beam imaging system to quantify the resolution, selectivity, geometric accuracy and contrast sensitivity of Co-60 DT. Although the resolution is severely limited by the penumbra cast by the ~2 cm diameter source, it is possible to identify high contrast objects on the order of 1 mm in width, and bony anatomy in anthropomorphic phantoms is clearly recognizable. Low contrast sensitivity down to electron density differences of 3% is obtained, for uniform features of similar thickness. The conventional shift-and-add reconstruction algorithm was compared to several variants of the Feldkamp-Davis-Kress filtered backprojection algorithm result. The Co-60 DT images were obtained with a total dose of 5 to 15 cGy each. We conclude that Co-60 radiotherapy units upgraded for modern conformal therapy could also incorporate imaging using filtered backprojection DT in the treatment beam. DT is a versatile and promising modality that would be well suited to image guidance requirements.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.004
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.006

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.004
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.010
GPT teacher head0.263
Teacher spread0.254 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2014
Admission routes1
Has abstractyes

Explore more

Same venueProceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE→Same topicAdvanced Radiotherapy Techniques→French-language works237,207→