MétaCan
Menu
Back to cohort
Record W2062303931 · doi:10.1079/ecep200422

Prediction of hydration status using multi-frequency bioelectrical impedance analysis during exercise and recovery in horses

2004· article· en· W2062303931 on OpenAlexaff
Gloria McKeen, MI Lindinger

Bibliographic record

VenueEquine and comparative exercise physiology · 2004
Typearticle
Languageen
FieldMedicine
TopicBody Composition Measurement Techniques
Canadian institutionsUniversity of Guelph
Fundersnot available
KeywordsBioelectrical impedance analysisBody waterExtracellular fluidMathematicsBiomedical engineeringMedicineChemistryInternal medicineBody mass indexBody weightExtracellular

Abstract

fetched live from OpenAlex

The present study tested the hypothesis that multi-frequency bioelectrical impedance analysis (MFBIA) can be used to provide reasonable estimates of body mass, total body water (TBW), extracellular fluid volume (ECFV) and plasma volume (PV) at rest, during exercise-induced dehydration and subsequent recovery. Seven exerciseconditioned horses were administered indicators for measurement of resting TBW, ECFV and PV. MFBIA measurements at 24 frequencies between 5 and 280 kHz were obtained at rest, during prolonged submaximal exercise and for up to 13 h of recovery with food and water provided. Impedance ‐frequency response curves were described by a double-exponential decay equation from which coefficients were used, together with height and length, to generate predictive equations for estimating body mass, TBW, ECFV and PV. Predictive equations for body mass, ECFV and PV provided reasonable estimates of the parameter at rest and during exercise and recovery that were within 6% of absolute values determined using indicators. Despite the inherent error in estimating absolute volumes, the technique allowed accurate (within 1%) determination of the change in compartment volumes within individual horses over time. The number of frequencies at which impedance was measured could be reduced to seven without sacrificing the accuracy of the impedance‐frequency relationships or the predictive equations ‐ this enabled a 70% reduction in data-acquisition time (to , 35 s) for each MFBIA measurement series. It is concluded that MFBIA can be used in individual horses to track changes in compartmental hydration status resulting from dehydration and rehydration.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.002

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0000.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.079
GPT teacher head0.323
Teacher spread0.244 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations14
Published2004
Admission routes1
Has abstractyes

Explore more

Same venueEquine and comparative exercise physiologySame topicBody Composition Measurement TechniquesFrench-language works237,207