MétaCan
Menu
← Back to cohort

Application of Oxygen Ion Implantation to Titanium Surfaces: Effects on Surface Characteristics, Corrosion Resistance, and Bone Response

2001· article· en· W2062723530 on OpenAlexvenueno aff
Takashi Sawase, Ann Wennerberg, K. Baba, Yoichi Tsuboi, Lars Sennerby, C. Johansson, T. Albrektsson

Bibliographic record

VenueClinical Implant Dentistry and Related Research · 2001
Typearticle
Languageen
FieldEngineering
TopicBone Tissue Engineering Materials
Canadian institutionsnot available
Fundersnot available
KeywordsCorrosionBiocompatibilityTitaniumMaterials scienceOxideLayer (electronics)Surface modificationTitanium oxideBiomedical engineeringIn vivoPolarization (electrochemistry)Surface layerMetallurgyChemical engineeringComposite materialChemistryMedicine

Abstract

fetched live from OpenAlex

BACKGROUND: The surface oxide layer of titanium plays a decisive role in determining biocompatibility. However, there are some reports demonstrating that the natural oxide film may not be sufficiently protective in the aggressive biologic environment. PURPOSE: The goal of this study was to examine the effectiveness of a thick oxide layer on corrosion resistance in vitro and the bone formation around titanium implants in vivo. MATERIALS AND METHODS: A plasma source ion implantation (PSII) method was used to increase the thickness of the surface oxide layer. Several instruments were employed to confirm the surface properties before and after the surface modification. Potentiodynamic polarization measurements in a phosphate-buffered saline (PBS) solution were carried out to investigate corrosion resistance in vitro. Bone formation around this surface-modified specimen was examined in a rabbit model and assessed in histomorphometry. RESULTS: Improved corrosion resistance was demonstrated by the potentiodynamic polarization measurements. Light microscopic histomorphometry showed that all implants were in contact with bone and had some proportion of bone within the threads at 4 weeks; however, there were no significant differences compared with as-machined controls. CONCLUSIONS: The results indicate that in spite of improved corrosion resistance in vitro, a thick oxide layer fabricated with the PSII method does not influence early bone formation around titanium implants in vivo.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.003

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.031
GPT teacher head0.352
Teacher spread0.321 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations36
Published2001
Admission routes1
Has abstractyes

Explore more

Same venueClinical Implant Dentistry and Related Research→Same topicBone Tissue Engineering Materials→French-language works237,207→