MétaCan
Menu
Back to cohort
Record W2063099556 · doi:10.1118/1.2241650

TU‐FF‐A3‐01: X‐Ray and Optical Monte Carlo Study of Thick, Segmented Scintillators for MV Imaging

2006· article· en· W2063099556 on OpenAlexaff
T. T. Monajemi, B. G. Fallone, S Rathee

Bibliographic record

VenueMedical Physics · 2006
Typearticle
Languageen
FieldPhysics and Astronomy
TopicRadiation Detection and Scintillator Technologies
Canadian institutionsUniversity of Alberta
Fundersnot available
KeywordsOpticsMonte Carlo methodDetective quantum efficiencyPhotonPhotodiodePhysicsScintillatorPhoton energyDetectorMaterials scienceImage quality

Abstract

fetched live from OpenAlex

Purpose: To study the imaging characteristics of thick, segmented, 2‐D CdWO 4 crystal‐photodiode detectors as a function of crystal height, septa material and optical reflectivity, x‐ray beam spectrum and beam divergence using a two‐step Monte Carlo approach involving both x‐ray photon transport at megavoltage (MV) energies and the optical photon transport in scintillator and photodiodes. Method and Materials: We have studied the spatial frequency dependent detective quantum efficiency (DQE) of thick, segmented, 2‐D CdWO 4 crystals in contact with silicon photodiode arrays. The energy deposited into the 3‐D voxels (1 × 1 × 1 mm 3 , septa thickness = 0.15 mm, fill factor = 72%) of the detector for each of the 6 and 3.5 MV x‐ray photons in a normally incident pencil beam was calculated using the DOSXYZnrc user code of the EGSnrc Monte Carol system. The isotropically emitted optical photons in each voxel were calculated using the average CdWO 4 optical yield and transported to the photodiode array using DETECT2000 optical Monte Carlo code. A 10° beam divergence angle was also simulated. The detector DQE was calculated using the spatial distribution of optical photons. Results: The DQE increases with the crystal height only if the reflectivity of the septa material is high (0.975). For poor reflectivity (0.65 and 0.8), the increase in the DQE of the taller crystals to MV photons is seriously offset (from 42% to less than 20% for 3 cm tall crystals) by the decreased probability of detecting optical photons. Similarly, the increase in DQE due to the lower energy photons is obtained if the high reflectivity of septa material is maintained for the detector. Beam divergence in thick crystals also reduces the DQE. Conclusion: High reflectivity of the septa in thick, segmented scintillation detectors is very important to achieve high DQE.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.430
Threshold uncertainty score0.539

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.008
GPT teacher head0.249
Teacher spread0.241 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2006
Admission routes1
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicRadiation Detection and Scintillator TechnologiesFrench-language works237,207