MétaCan
Menu
Back to cohort

Comparative Results Between Conventional and Computer-Assisted Pedicle Screw Installation in the Thoracic, Lumbar, and Sacral Spine

2000· article· en· W2063177025 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenueSpine · 2000
Typearticle
Languageen
FieldMedicine
TopicSpinal Fractures and Fixation Techniques
Canadian institutionsCentre Hospitalier Universitaire Sainte-JustineUniversité de Montréal
Fundersnot available
KeywordsMedicineLumbarCohortSurgeryLumbar spineMagnetic resonance imagingOrthodonticsNuclear medicineRadiologyInternal medicine

Abstract

fetched live from OpenAlex

STUDY DESIGN: A comparative study on the position of pedicle screws in patients treated surgically with and without computer assistance. OBJECTIVES: To evaluate the accuracy of computer-assisted pedicle screw installation, and to evaluate its clinical benefit as compared with conventional pedicle screw installation techniques. SUMMARY OF BACKGROUND DATA: In vitro and clinical studies have documented a significant rate of misplaced screws in the thoracolumbar area. Neurologic complications are recognized problems caused by screw misplacement. METHODS: Patients treated surgically with computer assistance were compared with a historical control group of patients treated surgically with conventional techniques in the same hospital and by the same surgical team. All screw positions were measured with a postoperative magnetic resonance tomography, and cortical effractions were categorized in 2-mm increments. Patients' charts also were reviewed to assess individual neurologic outcomes. RESULTS: The control cohort was composed of 100 patients, with 544 screws from T5 to S1. The computer-assisted cohort was composed of 50 patients, with 294 screws from T2 to S1. In the control cohort, 461 of 544 screws (85%) were found completely within their pedicles as compared with 278 of 294 screws (95%) correctly placed in the computer-assisted group (P < 0.0001). All 16 screws incorrectly placed with computer assistance were found 0.1 mm to 2 mm from the pedicle cortex. In the control cohort, 68 screws were found 0.1 mm to 2 mm, 10 screws 2.1 mm to 4 mm, and 5 screws more than 4 mm from the pedicle cortex. Seven patients in the control cohort were surgically retreated because of postoperative neurologic deficits, whereas no patients in the computer-assisted group were surgically retreated. CONCLUSIONS: Computer assistance can decrease the incidence of incorrectly positioned pedicle screws.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.907
Threshold uncertainty score0.308

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.043
GPT teacher head0.356
Teacher spread0.314 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it