MétaCan
Menu
Back to cohort
Record W2063601502 · doi:10.1111/aos.12275

Comparison of a new portable digital meniscometer and optical coherence tomography in tear meniscus radius measurement

2013· article· en· W2063601502 on OpenAlexaff
Stefan Bandlitz, Christine Purslow, Paul J. Murphy, Heiko Pult

Bibliographic record

VenueActa Ophthalmologica · 2013
Typearticle
Languageen
FieldMedicine
TopicOcular Surface and Contact Lens
Canadian institutionsUniversity of Waterloo
Fundersnot available
KeywordsOptical coherence tomographyMeniscusRADIUSOpticsOphthalmologyPhysicsMedicineComputer science

Abstract

fetched live from OpenAlex

PURPOSE: Non-invasive measurement of tear meniscus radius (TMR) is useful in the assessment of tear volume for dry eye diagnosis. This study investigates the agreement between a new, portable, slit-lamp mounted, digital meniscometer (PDM) and optical coherence tomography (OCT) in the measurement of human TMR. METHODS: Images of the tear meniscus at the centre of the lower lid of 30 normal subjects (8M, 22F; mean age 27.5 SD ± 9.6 years) were taken using the PDM and the OCT. On the PDM and OCT images, TMR was measured using imagej 1.46b software. The meniscus on the OCT images was subdivided vertically into three equal sections and the radius calculated for each: bottom (BTMR), centre (CTMR) and top (TTMR). The relationship between PDM and OCT measurements was analysed using Spearman's rank coefficient, and differences between PDM and OCT subsection measurements were evaluated using Bland-Altman plots. RESULTS: Tear meniscus radius measured with the PDM (0.25 ± 0.06 mm) and OCT (0.29 ± 0.09 mm) was significantly correlated (r = 0.675; p < 0.001). The mean differences between TMR using the PDM and the subsections from OCT showed that TMR measured with PDM was greater for BTMR (0.07 mm; CI 0.05-0.10; p < 0.001), similar for CTMR (-0.01 mm; CI -0.04 to 0.02; p = 0.636) and steeper for TTMR (-0.07 mm; CI -0.10 to -0.04; p < 0.001). CONCLUSIONS: Portable digital meniscometer and OCT measurements of the TMR are significantly correlated, suggesting that the new PDM is a useful surrogate for OCT in this respect. The PDM appears to measure the radius of the central section of the tear meniscus.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.028
Threshold uncertainty score0.533

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.055
GPT teacher head0.300
Teacher spread0.245 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations30
Published2013
Admission routes1
Has abstractyes

Explore more

Same venueActa OphthalmologicaSame topicOcular Surface and Contact LensFrench-language works237,207