MétaCan
Menu
← Back to cohort
Record W2063861183 · doi:10.1117/12.811177

Understanding quantification of microvascularity with high-frequency power Doppler ultrasound

2009· article· en· W2063861183 on OpenAlexaff
S. Pintér, James C. Lacefield

Bibliographic record

VenueProceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · 2009
Typearticle
Languageen
FieldMedicine
TopicCardiovascular Health and Disease Prevention
Canadian institutionsWestern University
Fundersnot available
KeywordsHigh frequency ultrasoundDoppler effectComputer sciencePower (physics)UltrasoundPower dopplerAcousticsPhysics

Abstract

fetched live from OpenAlex

High-frequency power Doppler imaging of angiogenesis can be challenging given the presence of small blood vessels and slow flow velocities. In the presence of substantial Doppler artifacts such as false-positive color pixels or undetected vessels, color pixel density (CPD) and related vascularity metrics do not provide accurate estimates of vascular volume fraction. As a step towards improved microvascular quantification, flow-phantom experiments were performed to establish relationships between CPD and wall filter cut-off velocity for various combinations of vessel size (160, 200, 250, 300, and 360 μm), flow velocity (4, 3, 2, 1, and 0.5 mm/s), and transducer frequency (30 and 40 MHz). Three distinct regions were observed in plots of CPD versus wall filter cut-off velocity: overestimation of CPD at low cut-offs, underestimation of CPD at high cut-offs, and a plateau at intermediate cut-offs. The CPD at the plateau closely matched the phantom's actual vascular volume fraction. The length of the plateau corresponded with the flow-detection performance of the Doppler system, which was assessed using receiver operating characteristic analysis. Color pixel density versus wall filter cut-off curves from analogous in vivo experiments exhibited the same shape, including a distinct CPD plateau. The similar shape of the flow-phantom and in vivo curves suggests that the presence of a plateau can be used to identify the best-estimate CPD value in an in vivo experiment. The ability to identify the best CPD estimate is expected to improve quantification of angiogenesis and anti-angiogenic treatment responses with power Doppler.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.005
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.002
Threshold uncertainty score0.011

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.005
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0000.001
Scholarly communication0.0010.002
Open science0.0010.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.021
GPT teacher head0.249
Teacher spread0.227 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2009
Admission routes1
Has abstractyes

Explore more

Same venueProceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE→Same topicCardiovascular Health and Disease Prevention→French-language works237,207→