Passive flow control in microdevices using thermally responsive polymer solutions
Bibliographic record
Abstract
Thermally responsive polymer solutions have previously been used in microchannels with integrated heaters for active valving. Here we present a detailed study of the rheological behavior of these complex fluids, suggesting the broad range of conditions under which active valving could be used, along with an investigation of their use for passive microflow control in which viscous heating leads to channel blockage. We discuss the scaling of viscous heating in the channels under constant flow rate and constant pressure drop conditions. In the case of pressure-driven flow through a microchannel, we demonstrate that viscous heating can cause periodic gel formation leading to flow instabilities. Velocity fields above and below the gel temperature were mapped using digital particle image velocimetry; above the gel temperature, flow fluctuations may be caused by the competing mechanisms of thermothickening and shear-thinning.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".