MétaCan
Menu
Back to cohort
Record W2064297726 · doi:10.1109/tbme.2014.2364959

Motion Estimation in Cardiac Fluorescence Imaging With Scale-Space Landmarks and Optical Flow: A Comparative Study

2014· article· en· W2064297726 on OpenAlexafffund
M. Rodriguez, Anders Nygren

Bibliographic record

VenueIEEE Transactions on Biomedical Engineering · 2014
Typearticle
Languageen
FieldMedicine
TopicAdvanced MRI Techniques and Applications
Canadian institutionsUniversity of Calgary
FundersNatural Sciences and Engineering Research Council of CanadaUniversity of Calgary
KeywordsComputer visionArtificial intelligenceScale-invariant feature transformOptical flowLandmarkComputer sciencePixelMotion estimationImage registrationTracking (education)Match movingOptical mappingMotion (physics)Pattern recognition (psychology)Feature extractionImage (mathematics)

Abstract

fetched live from OpenAlex

Motion artifacts are a major disadvantage of cardiac optical mapping studies. Pixel misalignment due to contraction is a main cause of the presence of gross motion artifacts in action potential recordings. This study is focused on methods for identifying landmarks and tracking the motion of cardiac tissue for preparations in optical mapping recordings. This is a first step toward our long-term goal to implement a landmark-based image registration technique to correct for pixel misalignment in cardiac optical mapping fluorescence videos and, hence, for gross motion artifacts. Preliminary results for the registration step are presented as an initial proof of concept. The characteristics of the optical mapping images are challenging, since their lack of contrast and well-defined features impose a limitation on the techniques than can be used for landmark selection and motion tracking. This paper compares results of motion estimation of the cardiac surface with two approaches that do not rely on high-contrast features: 1) Scale-invariant feature transform (SIFT) detected "keypoints," to be used as landmarks for motion tracking, as well as 2) a classical global optical flow (OF) algorithm. Both are applied to low-contrast and low-resolution cardiac fluorescence images. We demonstrate that the performance of SIFT is superior to that of OF for pixel motion tracking in cardiac optical mapping images with simulated motion. Results for action potential recovery and action potential duration calculation after landmark-based image registration show that SIFT landmark-based registration yields superior performance in this regard as well.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Methods · Consensus signal: none
Teacher disagreement score0.799
Threshold uncertainty score0.446

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.007
GPT teacher head0.265
Teacher spread0.258 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations12
Published2014
Admission routes2
Has abstractyes

Explore more

Same venueIEEE Transactions on Biomedical EngineeringSame topicAdvanced MRI Techniques and ApplicationsFrench-language works237,207