MétaCan
Menu
Back to cohort
Record W2064669467 · doi:10.1118/1.4711753

Feature‐based multibody rigid registration of CT and ultrasound images of lumbar spine

2012· article· en· W2064669467 on OpenAlexafffund
Abtin Rasoulian, Purang Abolmaesumi, Parvin Mousavi

Bibliographic record

VenueMedical Physics · 2012
Typearticle
Languageen
FieldEngineering
TopicMedical Imaging and Analysis
Canadian institutionsQueen's UniversityUniversity of British Columbia
FundersCanadian Institutes of Health Research
KeywordsArtificial intelligenceComputer visionFiducial markerImage registrationComputer scienceFeature (linguistics)Supine positionImaging phantomMedicineRadiologySurgery

Abstract

fetched live from OpenAlex

PURPOSE: Fusion of intraprocedure ultrasound and preprocedure CT data is proposed for guidance in percutaneous spinal injections, a common procedure for pain management. CT scan of the lumbar spine is usually collected in a supine position, whereas spinal injections are performed in prone or sitting positions. This leads to a difference in the spine curvature between CT and ultrasound images; as such, a single-body rigid registration approach cannot be used for the whole lumbar vertebrae. METHODS: To compensate for the difference in the spinal curvature between the two imaging modalities, a multibody rigid registration algorithm is presented. The approach utilizes a point-based registration technique based on the unscented Kalman filter (UKF), taking as input segmented vertebrae surfaces in both CT and ultrasound data. Ultrasound images are automatically segmented using a dynamic programming method, while the CT images are semiautomatically segmented using thresholding. The registration approach is designed to simultaneously align individual groups of points segmented from each vertebra in the two imaging modalities. A biomechanical model is developed to constrain the vertebrae transformation parameters during the registration and to ensure convergence. RESULTS: The proposed methodology is evaluated on human spine phantoms and a sheep cadaver. Registrations on phantom data have a mean target registration error (TRE) of 1.99 mm in the region of interest and converged in 87% of cases. Registrations on sheep cadaver have a mean target registration error of 2.2 mm and converged in 82% of cases. CONCLUSIONS: The proposed technique can robustly and simultaneously register several vertebrae extracted from CT images to the ultrasound volumes. The registration error below 2.2 mm is sufficient for most spinal injections.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.002
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.009
GPT teacher head0.254
Teacher spread0.245 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations30
Published2012
Admission routes2
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicMedical Imaging and AnalysisFrench-language works237,207