MétaCan
Menu
Back to cohort
Record W2064978519 · doi:10.1021/ac901696q

405 nm Absorption Detection in Nanoliter Volumes

2009· article· en· W2064978519 on OpenAlexafffund
Helen Waechter, Klaus Bescherer, Christoph J. Dürr, Richard D. Oleschuk, Hans‐Peter Loock

Bibliographic record

VenueAnalytical Chemistry · 2009
Typearticle
Languageen
FieldEngineering
TopicGas Sensing Nanomaterials and Sensors
Canadian institutionsQueen's University
FundersEli Lilly CanadaSchweizerischer Nationalfonds zur Förderung der Wissenschaftlichen ForschungOntario Centres of Excellence
KeywordsChemistryAbsorption (acoustics)Analytical Chemistry (journal)NanotechnologyChromatographyOptics

Abstract

fetched live from OpenAlex

Analytical UV absorption detection for microfluidic devices, capillary electrophoresis, and even high-performance liquid chromatography is hampered by the small detection volumes, short absorption paths, and the need to sample at a high rate with a stable background and low noise. Fiber-loop ring-down spectroscopy (FLRDS) permits absorption detection of dilute liquid samples in volumes as small as a few nanoliters, while being insensitive to light source fluctuations and permitting a millisecond temporal resolution. We demonstrate a FLRDS based detection scheme that is compatible in dimensions (<200 microm absorption path, 6.0 nL detection volume) and optical design (405 nm detection wavelength, fiber coupled) with existing separation systems. An optical/fluidic interface has been built that allows injection of laser light into the loop while also permitting delivery of the sample. The detection limit of tartrazine was determined to be 5 microM (30 fmol) corresponding to an absorption of 0.11 cm(-1). Equivalent results were obtained when detecting myoglobin, a heterocyclic pharmaceutical ingredient, and 5.17 microm diameter polystyrene beads.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.004
Threshold uncertainty score0.015

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0040.002

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.006
GPT teacher head0.198
Teacher spread0.192 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations27
Published2009
Admission routes2
Has abstractyes

Explore more

Same venueAnalytical ChemistrySame topicGas Sensing Nanomaterials and SensorsFrench-language works237,207