MétaCan
Menu
Back to cohort
Record W2064990990 · doi:10.1063/1.2361179

Gain and lifetime of GaInNAsSb narrow ridge waveguide laser diodes in continuous-wave operation at 1.56μm

2006· article· en· W2064990990 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenueApplied Physics Letters · 2006
Typearticle
Languageen
FieldPhysics and Astronomy
TopicSemiconductor Quantum Structures and Devices
Canadian institutionsInstitute for Microstructural Sciences
Fundersnot available
KeywordsLaserOptoelectronicsMaterials scienceContinuous waveDiodeDifferential gainCurrent (fluid)Semiconductor laser theoryOpticsElectrical engineeringPhysics

Abstract

fetched live from OpenAlex

The continuous-wave (cw) operation of GaInNAsSb lasers at 1560nm is reported. Light-current measurements were made before and after a 100h cw burn in at 20°C, during which a 3×890μm2 device with 72mA initial threshold current and 14mW maximum output power experienced a 15% drop in peak output power. These preliminary lifetime results provide insight into the reliability of GaInNAsSb active regions and reinforce the promise of this material for C-band devices. High-resolution modal gain spectra were extracted from the amplified spontaneous emission spectra acquired after the burn in, providing reliable values for the internal loss, transparency current, and differential gain.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.035
Threshold uncertainty score0.858

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.008
GPT teacher head0.208
Teacher spread0.200 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it