Suture refixation and recentration of a subluxated capsular tension ring–capsular bag–intraocular lens complex
Bibliographic record
Abstract
We describe a 3-point ab externo technique to refixate and recenter a subluxated Cionni capsular tension ring (CTR)-intraocular lens (IOL)-capsular bag complex to the sclera. A 9-0 polypropylene suture on a curved needle is looped through the eyelet of the CTR and back through a Hoffman scleral tunnel. Two other sutures passed in a similar fashion through the fibrotic continuous curvilinear capsulorhexis (CCC) edge are used to complete a tripod fixation, which centers and stabilizes the IOL. This surgical approach avoids the surgical trauma of removing and replacing a subluxated CTR-IOL-capsular bag complex, retains the optimal anatomical position, and ensures centration of the IOL.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.001 | 0.001 |
| Meta-epidemiology (narrow) | 0.001 | 0.001 |
| Meta-epidemiology (broad) | 0.001 | 0.002 |
| Bibliometrics | 0.002 | 0.001 |
| Science and technology studies | 0.001 | 0.001 |
| Scholarly communication | 0.001 | 0.002 |
| Open science | 0.001 | 0.001 |
| Research integrity | 0.002 | 0.003 |
| Insufficient payload (model declined to judge) | 0.001 | 0.001 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".