The targeting accuracy of a preclinical MRI‐guided focused ultrasound system

2015· article· en· W2065095088 on OpenAlexafffund
Nicholas Ellens, Ilya Kobelevskiy, Anthony Chau, Adam C. Waspe, Robert Staruch, Rajiv Chopra, Kullervo Hynynen

Bibliographic record

VenueMedical Physics · 2015
Typearticle
Languageen
FieldMedicine
TopicUltrasound Imaging and Elastography
Canadian institutionsHospital for Sick ChildrenUniversity of TorontoSunnybrook Health Science Centre
FundersCanada Research Chairs
KeywordsUltrasoundBiomedical engineeringFocus (optics)Focused ultrasoundMagnetic resonance imagingTransducerNuclear medicineMedicineComputer scienceRadiologyAcousticsPhysicsOptics

Abstract

fetched live from OpenAlex

PURPOSE: Assess the accuracy, precision, and sources of error using a preclinical MR-guided focused ultrasound system. METHODS: A preclinical focused ultrasound system, described previously [Chopra et al., Med. Phys. 36(5), 1867-1874 (2009)], was tested on a benchtop and with 3T GE, 3T Philips, and 7 T Bruker MR scanners for spatial targeting accuracy and precision. Randomly distributed water-filled holes drilled into a polystyrene plate were imaged using MRI and targeted using treatment planning software. The ultrasound focus of a 72 mm, f-number 0.8, 1.16 MHz transducer was aimed at the target locations, and 1-2 s continuous-wave sonications were performed on clear polystyrene plates to create localized spots of melted plastic. The distance between target and observed locations was measured and analyzed. Retrospective analysis of targeting accuracy was performed on preclinical data obtained from other experiments at their institution using the same system. RESULTS: The results suggest that the sources of targeting error under MR guidance can be roughly separated into three components--normally distributed random error; constant shift from inaccuracy in detection of the initial ultrasound focus; and angular misalignment between MR and focused ultrasound (FUS) coordinates. The lower bound on the targeting error was estimated to be 0.25 ± 0.13 mm, while the maximum observed targeting error did not exceed 2 mm. Measures required to reduce errors and improve targeting were developed to reduce the registration and misalignment errors such that maximum error was reduced to 0.36 ± 0.14 mm. Retrospective in vivo analysis indicated that the error was 1.02 ± 0.43 mm, including error extrinsic to the system. CONCLUSIONS: The FUS system, as described, is capable of precise and accurate sonications. The largest source of error--misregistration of the coordinate systems of the scanner and ultrasound system--was addressed which reduced the error to 0.36 ± 0.14 mm, sufficient for many preclinical applications.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.009
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMetaresearch
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: Not applicable
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.398
Threshold uncertainty score0.999

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.009
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.038
GPT teacher head0.324
Teacher spread0.286 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designNot applicable
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations22
Published2015
Admission routes2
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicUltrasound Imaging and ElastographyFrench-language works237,207