MétaCan
Menu
Back to cohort
Record W2065095088 · doi:10.1118/1.4903950

The targeting accuracy of a preclinical MRI‐guided focused ultrasound system

2015· article· en· W2065095088 on OpenAlexafffund
Nicholas Ellens, Ilya Kobelevskiy, Anthony Chau, Adam C. Waspe, Robert Staruch, Rajiv Chopra, Kullervo Hynynen

Bibliographic record

VenueMedical Physics · 2015
Typearticle
Languageen
FieldMedicine
TopicUltrasound Imaging and Elastography
Canadian institutionsHospital for Sick ChildrenUniversity of TorontoSunnybrook Health Science Centre
FundersCanada Research Chairs
KeywordsUltrasoundBiomedical engineeringFocus (optics)Focused ultrasoundMagnetic resonance imagingTransducerNuclear medicineMedicineComputer scienceRadiologyAcousticsPhysicsOptics

Abstract

fetched live from OpenAlex

PURPOSE: Assess the accuracy, precision, and sources of error using a preclinical MR-guided focused ultrasound system. METHODS: A preclinical focused ultrasound system, described previously [Chopra et al., Med. Phys. 36(5), 1867-1874 (2009)], was tested on a benchtop and with 3T GE, 3T Philips, and 7 T Bruker MR scanners for spatial targeting accuracy and precision. Randomly distributed water-filled holes drilled into a polystyrene plate were imaged using MRI and targeted using treatment planning software. The ultrasound focus of a 72 mm, f-number 0.8, 1.16 MHz transducer was aimed at the target locations, and 1-2 s continuous-wave sonications were performed on clear polystyrene plates to create localized spots of melted plastic. The distance between target and observed locations was measured and analyzed. Retrospective analysis of targeting accuracy was performed on preclinical data obtained from other experiments at their institution using the same system. RESULTS: The results suggest that the sources of targeting error under MR guidance can be roughly separated into three components--normally distributed random error; constant shift from inaccuracy in detection of the initial ultrasound focus; and angular misalignment between MR and focused ultrasound (FUS) coordinates. The lower bound on the targeting error was estimated to be 0.25 ± 0.13 mm, while the maximum observed targeting error did not exceed 2 mm. Measures required to reduce errors and improve targeting were developed to reduce the registration and misalignment errors such that maximum error was reduced to 0.36 ± 0.14 mm. Retrospective in vivo analysis indicated that the error was 1.02 ± 0.43 mm, including error extrinsic to the system. CONCLUSIONS: The FUS system, as described, is capable of precise and accurate sonications. The largest source of error--misregistration of the coordinate systems of the scanner and ultrasound system--was addressed which reduced the error to 0.36 ± 0.14 mm, sufficient for many preclinical applications.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.010
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.015

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0030.010
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.038
GPT teacher head0.324
Teacher spread0.286 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations22
Published2015
Admission routes2
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicUltrasound Imaging and ElastographyFrench-language works237,207