Double-layer estimation of intra- and extracerebral hemoglobin concentration with a time-resolved system
Why this work is in the frame
A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.
Bibliographic record
Abstract
We present in vivo measurements of baseline physiology from five subjects with a four-wavelength (690, 750, 800, and 850 nm) time-resolved optical system. The measurements were taken at four distances: 10, 15, 25, and 30 mm. All distances were fit simultaneously with a two-layered analytical model for the absorption and reduced scattering coefficient of both layers. The thickness of the first layer, comprising the skin, scalp, and cerebrospinal fluid, was obtained from anatomical magnetic resonance images. The fitting procedure was first tested with simulations before being applied to in vivo measurements and verified that this procedure permits accurate characterization of the hemoglobin concentrations in the extra- and intracerebral tissues. Baseline oxyhemoglobin, deoxyhemoglobin, and total hemoglobin concentrations and oxygen saturation were recovered from in vivo measurements and compared to the literature. We observed a noticeable intersubject variability of the hemoglobin concentrations, but constant values for the cerebral hemoglobin oxygen saturation.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it