MétaCan
Menu
Back to cohort
Record W2065336990 · doi:10.1002/jbm.a.31018

Fibrinolytic properties of lysine‐derivatized polyethylene in contact with flowing whole blood (Chandler loop model)

2006· article· en· W2065336990 on OpenAlexaff
W. Glenn McClung, D.E. Babcock, John L. Brash

Bibliographic record

VenueJournal of Biomedical Materials Research Part A · 2006
Typearticle
Languageen
FieldBiochemistry, Genetics and Molecular Biology
TopicProtease and Inhibitor Mechanisms
Canadian institutionsMcMaster University
Fundersnot available
KeywordsPlasminLysineThrombusThrombolysisPolymerMaterials scienceWhole bloodPolyethyleneAdsorptionAmino acidContact anglePolymer chemistryPlateletChemistryBiochemistryOrganic chemistrySurgeryComposite materialBiologyMedicineEnzymeImmunology

Abstract

fetched live from OpenAlex

This article reports on the concept of a fibrinolytic surface based on the preferential adsorption of endogenous plasminogen from blood. Data are presented indicating that such a surface, when pretreated with tissue-type plasminogen activator (tPA), is able to dissolve nascent thrombus generated in contact with flowing whole blood. Polyethylene (PE) surfaces were modified by attaching a lysine-containing polymer using photochemical methods as reported previously (McClung et al., J Biomed Mater Res 2000;49:409-414). The lysine residues were bound chemically to the polymer via the alpha-amino groups leaving the epsilon-amino groups free (epsilon-Lys surface). Control surfaces were (a) unmodified PE, (b) PE modified with the coating polymer containing no lysine, and (c) PE modified with the polymer containing lysine bound via the epsilon-amino group. The materials in tubing form were evaluated in contact with nonanticoagulated flowing human whole blood in a modified Chandler Loop experiment. They were first treated with tPA to allow activation of adsorbed plasminogen to plasmin. It was found that thrombus formation was initiated within 15-25 min (depending on donor blood) on all surfaces, as indicated by the formation of platelet aggregates. On the controls (including the lysine-containing material in which the epsilon-amino group was used in the binding reaction) thrombogenesis continued till the tubing was occluded and blood flow ceased. On the epsilon-Lys surface, thrombogenesis was interrupted at various stages depending on the donor blood; in all cases any thrombus generated was dissolved within minutes. It was shown that thrombolysis was due to the fibrinolytic action of plasmin generated at the surface and not to plasmin formed by traces of tPA released into the blood. This work provides further evidence of the efficacy of this approach to the development of a fibrinolytic surface.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.364

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.033
GPT teacher head0.285
Teacher spread0.252 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations31
Published2006
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Biomedical Materials Research Part ASame topicProtease and Inhibitor MechanismsFrench-language works237,207